850 U.S. 9
Fishkill, NY 12524
845-896-4328

Local Reviews
for rhinebeck, ny

Rated 5.0 out of 5 stars based on 5 customer reviews

Great

Your outfit gets a 10. Noah is a well trained professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great company

Billy came to give me an estimate on replacing my AC condenser and furnace. He was terrific. Explained things very clearly, and the pros and cons of different options. Highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service - fast, efficient, and informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Servicd!


Response from Folkes Heating, Cooling and Burner Service:

Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Efficient and informative


Response from Folkes Heating, Cooling and Burner Service:

We are here whenever you need us. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rhinebeck, ny

Chrish@folkeshomeservices.com

Chrish@folkeshomeservices.com Job Checkin

Customer said fan wasn’t coming on this afternoon and wasn’t maintain temperature. Looked over unit changed Merv filter 20x20x4 which was pretty dirty, inside air handler looked good, tested pressures which were normal, went over thermostat with customer. System operational and working as it should. Please mail invoice to customer.


Noah  D.

Noah D. Job Checkin

Found the blower not coming on, tested the board found it was good, thought it was the blower until I found a temperature switch in line with the cool wire on the blower. The switch is not needed on the system so I spliced the wires and connected them, the system worked good after that.


Scott Y.

Scott Y. Job Checkin

Performed tune up for air conditioning. Checked delta t, evaporator coil, cleared trap, necked blower and wiring for air handler. Checked thermostat operation. Checked pressures, capacitor and contactor. System is operating normally.


Margaret M.

Margaret M. Job Checkin

Estimate for new Condensor and coil 1.5 ton Seer. Recently had other system replaced by another company and felt she was overcharged. Single family home - Propane gas furnace - Currently has central air


Margaret M.

Margaret M. Job Checkin

Ac Tune Up, and blower wheel cleaning on bedroom wall unit.


Margaret M.

Margaret M. Job Checkin

Completed ac tune up. Checked indoor blower, delta t, condensate pump, drain line, running pressures, contactor, capacitor, fan and compressor amps. System is operating normally.


Margaret M.

Margaret M. Job Checkin

Performed annual maintenance on air conditioning system. Changed one Merv Filter customer provided. Checked blower wheel which was clean, cleared drain lines, and tested blower capacitor which tested fine. At the condenser outside checked pressures and temperatures, also tested capacitor at outside unit which tested fine. System operational ready for summer.


Margaret M.

Margaret M. Job Checkin

Re wired zoning for proper operating. Moved Digital air temperature sensor from return to supply duct. Pressure tested, evacuated and opened valves on both ductless heat pump and central air system. Corrected wiring for condenser at zoning panel and configured thermostats for cooling. Checked all systems in heating and cool modes.


Greg M.

Greg M. Job Checkin

Found heat pump locked out on short cycle lockout again. Reset system and found that after 20mins high side pressure is getting to 600psi and system cycling on/off on high pressure switch. Checked filter, ductwork and air flow. Spoke to manufacturer rep., system may be overcharged. Removed charge and and put back in factory charge. Also couch in downstairs living room blocking first floor return.


Greg M.

Greg M. Job Checkin

Found heat. Pump locked out on 3 red flash error code. Short cycling lockout. Reset system checked refrigerant pressures, normal. Emergency heat not working either. Found wired incorrectly at thermostat and air handler. Corrected wiring and checked operation. Need to return next Monday for further troubleshooting on heat pump.


Danny B.

Danny B. Job Checkin

Reset condenser, cycled on and off three times, ran for about 10 minutes, system operational.


Greg M.

Greg M. Job Checkin

checked operation of system. Running normally. Noise complaint of loud rattling noise in dining room under unit. Did hear noise once. Sounded like something rattling in supply plenum. Looked into plenum with camera did not see anything, and did not hear noise again after several cycles.


Margaret M.

Margaret M. Job Checkin

Replacement One 10 Ton R-410A Packaged Heat Pump Unit on back side of main building, York Model #XP120C00R2A1AAA1A, One 12.5 Ton R-410A Packaged Heat Pump Unit on Rooftop of main building, York Model #XP150C00R2A1AAA1A, crane & machinery needed for removal of old & installation of new units, licensed electrician for any necessary electrical work, removal and disposal of old units, all permits required by building department for job ***Removal/re-installation of fence around unit on back of building not included*** Total:$27,980.00 Balance Due:$13990.00


Greg M.

Greg M. Job Checkin

Completed annual maintenance on ductless heat pump with two indoor zones.


Greg M.

Greg M. Job Checkin

New install. Customer stated to warm on second floor. Downflow air handler in second floor closet. No access to ductwork, zoning not an option. Running pressures 126/287, sh 3, sc 16, td 18. 5 degree difference from first to second floor. ECM blower in high speed. Thermostat on first floor. System operating normally.