Have any feedback for us? We'd love to hear it! Call us at (205) 417-2030 and let us know how we are doing.
Arrived on call to perform cooling inspection and heat, cycled systems checked all components and cleaned/flushed drains and outdoor coils. Compressor rla 15.40=8.78 Fan fla 1.40=1.22 Suction psi 120 Liquid psi 299 Supply temp 53 Return temp 73 Outdoor temp 80 Sub cooling 10 Capacitor 45/5=13/3 (replaced) new 45/5 Mini split Compressor rla 7.40=3.78 Fan fla 0.50=0.35