Job Checkin

Met with Michael and proceeded to perform a PTU on a Peerless gas fired boiler. The boiler is wedged up against the wall with the water heater and a laundry sink basin up against it…. Difficult access scenario. I inspected the following items: all electrical wiring with their connections, the rollout switch, the spill switch, igniter, flame sensor, pilot assembly, the burners, gas valve, exhaust and all associated piping and plumbing. Upon inspection in I found considerable amount of debris an top of the burners hood assembly. The equipment is full of lint throughout and the burners are in need of service with the gas pressure checked. Upon lighting the unit has flame rollout and the gas pressure appears to be excessive. I took a video of the start up sequence and showed Michael. He agreed to a burner cleaning service and a gas pressure check. Michael was very satisfied with the service.