Kevin A.

Kevin A. Job Checkin

Arrived at the job for a new Fujitsu installation. Turned off the power and disconnected all wiring to the unit. Next we removed all the gas lines, return duct, exhaust and other miscellaneous items. We brought the new furnace up to the attic and fitted it in place. We connected the ac coil cabinet and return duct. We re-routed and connected all electrical wiring including the low voltage. We reassembled all the gas lines, purged and checked for leaks. Installed the exhaust lines and taped the joints. We fired up the furnace and allowed it to run and cycle for a few minutes, Job completed.


Mike D.

Mike D. Job Checkin

Met with Paul and proceeded to perform a Ptu on a oil fired boiler. I replace the oil tank filter along with the pump strainer. I removed the gun assembly, cleaned it, replaced the nozzle and checked for specs. I reassembled the gun assembly, restored power and turned up the thermostat. I bathe oil lines and observed the boiler run, cycle and reach temperature. All is good. No issues to report at this time. Customer satisfied with service.


Kevin A.

Kevin A. Job Checkin

Arrive to performs GW Tune Up. Set thermostat call for heat. Observed system operation. Serviced air filters, service burners, safety’s, gas valve and electrical connection. Recommended: Inducer motor replacement and also gas valve. Customer will call office when he makes a decision. System operation ok in this time. Customer is happy with the service.


Miguel  C.

Miguel C. Job Checkin

Arrived to perform system evacuation and remove condenser unit, reviewed attic job site, customer understands we will return as soon as GGEHS receives equipment


Miguel  C.

Miguel C. Job Checkin

Arrived to perform system evacuation and remove condenser unit, reviewed attic job site, customer understands we will return as soon as GGEHS receives equipment


Miguel  C.

Miguel C. Job Checkin

Arrived to perform system evacuation and remove condenser unit, reviewed attic job site, customer understands we will return as soon as GGEHS receives equipment


Miguel  C.

Miguel C. Job Checkin

Arrived to perform system evacuation and remove condenser unit, reviewed attic job site, customer understands we will return as soon as GGEHS receives equipment


Kevin A.

Kevin A. Job Checkin

Arrive to performs OW TUNE UP. Set thermostat call for heat. Observed system operation. Replace 2 Oil filter, nozzle, safety’s, check oil valve, electrical connection. Recommended (Triple saving combo) Customer declined the Options. System operation ok in this time.


Cari B.

Cari B. Job Checkin

Arrived to customer's home on Sunday July 10, 2022. Customer is complaining of no water. We just installed a new well tank. I observed zero pressure on the gauge. This was after the customer had been using both hot and cold with no problems for last two days. Found that well pump is seized. Customer needs a new well pump. Discussed this with customer and issued several estimates with options. Customer refused to sign invoice and had another company enter the home as I was leaving.


Kevin A.

Kevin A. Job Checkin

Unit in basement Arrived to perform Ac tune up. Customer has no concerns Set thermostat call for cooling Observe indoor unit, service duct work, air filter, electrical connection, condensate system, coils and performed temperature readings Return: 69.9* F Supply: 59.8* F Observe out door unit, service coils, electrical compartment, motors, refrigerate lines Ac system operating ok at this time. Unit in 2 floor Arrived to perform Ac tune up. Customer has no concerns Set thermostat call for cooling Observe indoor unit, service duct work, air filter, electrical connection, condensate system, coils and performed temperature readings Return: 69.2* F Supply: 55.5* F Observe out door unit, service coils, electrical compartment, motors, refrigerate lines Ac system operating ok at this time.


Cari B.

Cari B. Job Checkin

Arrived to customer's home. Customer approved to proceed with service. Replaced well tank including fittings and valves. Replaced hose faucet with frost wall hydrant. Installed new 3/4" ball valves full port isolation valves. Customer is aware that tech will have to return on 7/8/22. Service was placed on hold and will be completed on 7/8/22. Customer was satisfied with today's service.


Casey M.

Casey M. Job Checkin

Arrive at the customer's house He was upset because less than a month ago, he said that a technician had come to do an Ac tune up and told him that everything was fine, and I charge him for making an acid wash condenser outdoor unit. Within a few days, the customer turned on his unit and the unit no longer cooled down. He scheduled a schedule to see what was going on, my diagnosis is that his minis split system has a leak. It is necessary to do a leak test with nitrogen and perform an evacuate and recharge afterwards. The customer says that a year ago he paid $3,000 for this problem and it is not fair that he still has it and has to pay for it again. He is very angry. Fix 2 flaps that were loose and add freon. The client was happy with the work. He wants to talk to the office in case he has this problem again, don't pay for a nitrogen leak test and evacuate


Casey M.

Casey M. Job Checkin

What is a customers house to unclog toilet, was only a customers house for a total of five minutes between chatting take a payment and doing the job. Everything went smooth and toilet is unclogged


Casey M.

Casey M. Job Checkin

Arrived to perform AC tuneup Customers states no concerns Set at for cooling Observed indoor unit, serviced air filter, duct work, coils, motor, condensation system electrical connections and took temperature readings Observed outdoor unit. Services coils, electrical compartment, coils, refrigerant lines and disconnect AC is operating ok at this time


Casey M.

Casey M. Job Checkin

Cleaning condenser