Brad F.

Brad F. Job Checkin

Arrived to customers home to give options on a new water filtration system and maybe a softener as well. Took pictures of current whole house filter and wrote up options including more advanced systems for filtration and sanitizing. Customer satisfied with service today


Mike D.

Mike D. Job Checkin

Customer refused to pay.


Luis  C.

Luis C. Job Checkin

Arrive at the customer house, the compressor makes a very loud noise, but his unit works good, he wants estimates to change the unit in the future. The customer told me that the reason he call was to see if we can move a unit to another place to be able to change the oil tank. I explained to the customer what is the process and he rejected.


Luis  C.

Luis C. Job Checkin

Arrive at the customer house, the compressor makes a very loud noise, but his unit works good, he wants estimates to change the unit in the future. The customer told me that the reason he call was to see if we can move a unit to another place to be able to change the oil tank. I explained to the customer what is the process and he rejected.


Luis  C.

Luis C. Job Checkin

Arrive at the customer house, the compressor makes a very loud noise, but his unit works good, he wants estimates to change the unit in the future. The customer told me that the reason he call was to see if we can move a unit to another place to be able to change the oil tank. I explained to the customer what is the process and he rejected.


Luis  C.

Luis C. Job Checkin

Arrive at the customer house, the compressor makes a very loud noise, but his unit works good, he wants estimates to change the unit in the future. The customer told me that the reason he call was to see if we can move a unit to another place to be able to change the oil tank. I explained to the customer what is the process and he rejected.


Cari B.

Cari B. Job Checkin

Customer had ceiling damage due to an ac condensation leak. The unit was pitched incorrectly. We noticed the floor is not level. Pitched the air handler correctly.


Casey M.

Casey M. Job Checkin

Received work order to service 2 AC units. Performed the annual maintenance service on both units. Checked the coils for rust, blockage, dirt and leaks. Installed anti microbial tablets. Brushed and flushed the condensate drain lines. Customer complained of not being able to shut off the downstairs unit. Began troubleshooting process. Removed the thermostat, unit would not turn off. Moved to the outside condenser checked the electrical junction box for miscellaneous issues, all is good including the circuit board. Contacted Amana tech support to assist in troubleshooting. I was able to trace the issue to the digital signal control box. I was able to reset the components and the AC unit turned off. Upon double checking and testing the unit for proper operation. The unit turned on but does not shut off. The issues are within the digital signal control box. Electrician is needed. Called the office and spoke with management, I was told Customer has an extended warranty and should not be c


Casey M.

Casey M. Job Checkin

WT PTU


Casey M.

Casey M. Job Checkin

No heat


Brian K.

Brian K. Job Checkin

air flow issue


Philip G.

Philip G. Job Checkin

Hpptu


Philip G.

Philip G. Job Checkin

Heat Pump Diagnostic


Hilary V.

Hilary V. Job Checkin

Performed a system recovery test on the 2 zone heat pump system and recovered. Performed system evacuation.


Hilary V.

Hilary V. Job Checkin

Heat Pump Service