5349 Dupont Road
Parkersburg, WV 26101
304-863-3553

Local Reviews
for harrisville, wv

Rated 4.6 out of 5 stars based on 8 customer reviews

Good service, professional guys too!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!!

Friendly and informative and proactive


Response from Grogg's Home Services:

We are incredibly grateful that you took the time out to leave us a 5-Star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful Service!

They did an amazing job and explained everything very well!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

They installed a new furnace and ac for me and did a fantastic job! They had everything installed and working great in no time at all! Very nice people to work with!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

I really like Travis. He is so nice and courteous. Knows what he is doing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very personable

Explaining everything very well, very personable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was ok

Service was ok. Didn't like the attitude. I felt like I was being called a liar about the circumstances. Also this is the second time this guy has come out and found that something hadn't been done right. I have had the humidifier for 2 years and am just now being told it was not hooked up. Felt like he was saying I had done something to unhook it. I had to pay for something that should have been done 2 years ago.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for harrisville, wv

Matthew G.

Matthew G. Job Checkin

Split system using 20x25x4 filter. All checks good at this time and system is operating properly.


Matthew G.

Matthew G. Job Checkin

2007 Goodman split system using 16x25x1 filter. Customers mentioned noticing the example of : asking system to cool to 73 and it may pass that number and they still hear the system running. One explanation of the sound I found was the fan function at t-stat was set to on rather than auto, allowing the blower motor to continuously run. For the temp difference, the t-stat has a 1 degree leniency for its threshold, (if asking for 73, won’t shut off til it hit 72), combined with continuos fan to circulate and mild temperatures this year, the circulating air has the potential to further drop the temp a degree if it isn’t having to fight higher ambient temps. All mechanical inspections today I found no issue and system is operating within normal ranges.


Alex G.

Alex G. Job Checkin

Performed heating and cooling check. Everything is running as it should. Customer will talk with wife about maintenance plan. Customer mentioned getting a new filter, left a quote for filter upgrade. Highly recommend surge protectors to protect equipment. Left a quote for that.


Alex G.

Alex G. Job Checkin

Performed cooling maintenance for customer. Unit is older train but still working fine. Everything looks good. Customer is buying virus hunter duct cleaning. Included iaq for this package is 120v surge protector and reme halo. Duct cleaners will need to bring those and install. Customer is approved through GreenSky and will pay with that. Also left quote for 40 gal electric hot water tank. Both pipes are 3/4” copper.


Alex G.

Alex G. Job Checkin

Replaced gas valve under warranty and set gas pressure


John B.

John B. Job Checkin

No issues found with system. To hear customer experience it sounds like the delay function. Explained to customer and offered to make some adjustments in thermostat. Customer did not want to change settings. We did go ahead and change air filter while here today. Spoke with customer about adding an air cleaner to system to help with dust in the home.


Greg C.

Greg C. Job Checkin

Replace existing furnace


John B.

John B. Job Checkin

24 yr old furnace has multiple issues. Only blower was running when I arrived. Found that the temperature limit switch was unable to reset itself. Furnace is overheating due to age of equipment and dirt in the system that has accumulated. Combustion analysis shows higher levels of carbon monoxide in the flue vent. The drain on furnace has been disconnected and it dripping into a container that has to be dumped. Drain should be hooked up to a trap to prevent a vacuum that would keep the unit from draining properly. Also customer has issues with thermostat. Given the age of unit and multiple issues it is not recommended to repair. Customer is getting an estimate to replace unit today 1-3pm.


Chris D.

Chris D. Job Checkin


Matthew G.

Matthew G. Job Checkin

Performed Platinum Comfort Club Membership Tune-Up on Heating System 2009 Coleman modular furnace and Rheem a/c using (2) 16x20x1 filters. Found blower motor run capacitor well out of range rated for a 7.5mfd and replaced it. Heavy build up on blower motor and wheel, cleaned what was possible however would need to pull motor to address the wheel housing itself. Good gas pressures and operation during check. On outdoor unit thoroughly cleaned condenser coil and found dual cap rated for 50/3mfd low on compressor side. Due to time of season customer wished to wait to address the cap if needed when spring comes around. Good line temp on cooling. Outdoor unit doesn’t have preferred clearing between back side of unit and the house but overall is operating as well as it can. Homeowner will establish Cozy HVAC today, but once planned electrical work is done, plan to add their second system to agreement.

Performed Platinum Comfort Club Membership Tune-Up on Heating System
2009 Coleman modular furnace and Rheem a/c using (2) 16x20x1 filters. Found blower motor run capacitor well out of range rated for a 7.5mfd and replaced it. Heavy build up on blower motor and wheel, cleaned what was possible however would need to pull motor to address the wheel housing itself. Good gas pressures and operation during check. On outdoor unit thoroughly cleaned condenser coil and found dual cap rated for 50/3mfd low on compressor side. Due to time of season customer wished to wait to address the cap if needed when spring comes around. Good line temp on cooling. Outdoor unit doesn’t have preferred clearing between back side of unit and the house but overall is operating as well as it can. Homeowner will establish Cozy HVAC today, but once planned electrical work is done, plan to add their second system to agreement.

Chris D.

Chris D. Job Checkin

Replaced limit switch and adjusted gas pressure down to help with the temperature rise. Tested operation, system is functioning well.


Epson E.

Epson E. Job Checkin

Service Call Fee: Main limit switch failed. Needs replaced. Will order and schedule repair.

Service Call Fee:

Main limit switch failed. Needs replaced. Will order and schedule repair.

Matthew G.

Matthew G. Job Checkin


Shawn L.

Shawn L. Job Checkin


Matthew G.

Matthew G. Job Checkin

Performed Platinum Comfort Club Membership Tune-Up on Heating System 2018 Ameristar heat pump w/ (approx 18x22x1) washable filter. All checks good at this time. Electric emergency heat, no gas present.

Performed Platinum Comfort Club Membership Tune-Up on Heating System
2018 Ameristar heat pump w/ (approx 18x22x1) washable filter. All checks good at this time. Electric emergency heat, no gas present.