Service No Charge Upon inspection found unit to have a leak on the drain line that was not glued good. Reglued 90 on drain line

Service No Charge
Upon inspection found unit to have a leak on the drain line that was not glued good. Reglued 90 on drain line

Kyle P.

Kyle P. Job Checkin


Matthew S.

Matthew S. Job Checkin


Matthew S.

Matthew S. Job Checkin


Doug H.

Doug H. Job Checkin

Performed 17 Point Labor Warranty Check extending Labor Warranty for a one year period.needed to add 4.11 oz of refrigerant due to new furnace install

Performed 17 Point Labor Warranty Check extending Labor Warranty for a one year period.needed to add 4.11 oz of refrigerant due to new furnace install

Corey B.

Corey B. Job Checkin

Service Call back both downstairs furnaces have blown fuses on the control board. replaced fuses. systems operating normally. possible overcurrent or surge situation advised customer to keep an eye on the system and call if it happens again.

Service Call back

both downstairs furnaces have blown fuses on the control board. replaced fuses. systems operating normally. possible overcurrent or surge situation

advised customer to keep an eye on the system and call if it happens again.

Kyle P.

Kyle P. Job Checkin

Service No Charge Furnace electric with ac the evaporator coil is extremely dirty preventing the water to drain into the pan drains are clear but coils is plugged.

Service No Charge
Furnace electric with ac 
the evaporator coil is extremely dirty preventing the water to drain into the pan drains are clear but coils is plugged.

Kyle P.

Kyle P. Job Checkin

Service No Charge did find unit locked out on water circuit open did find pump to be uphill of drain possibly causing issue cleared fault did adjust fan speed to accommodate heat rise on econet did run furnace for a pump cycle did drain and pump no issue

Service No Charge
did find unit locked out on water circuit open 
did find pump to be uphill of drain possibly causing issue cleared fault 
did adjust fan speed to accommodate heat rise on econet 
did run furnace for a pump cycle did drain and pump no issue

Corey B.

Corey B. Job Checkin

maintenance check


Doug H.

Doug H. Job Checkin

RUN CAPACITOR * STAND ALONE - 2 To 35 MFD, 370/440V

RUN CAPACITOR * STAND ALONE - 2 To 35 MFD, 370/440V

John K.

John K. Job Checkin

Platinum membership heating and cooling tune up system operating properly at this point.


Greg P.

Greg P. Job Checkin

One of the downstairs unit capacitor had failed, replaced, ok at this time. Upstairs unit was running, changed filter, added 1 lb 410a, ok at this time.