Chris D.

Chris D.


Job Checkin

Service Call Platinum Client The system is 17 years old, and the overall condition is inferior. The sequencer shorted out, causing the heat strip to stay on when it should have been off. Identified burnt electrical wiring and safety device. Refer to photos. These parts were likely damaged by the excessive water draining off the coil when the drain plugged up. The evaporator coil itself is in terrible condition and is likely where the refrigerant has been leaking out. Corrosion, in combination with age, has eaten away the aluminum and would need to be replaced. My professional opinion is not to have this system repaired. The overall condition, coupled with the age and the fact that it is still running on R22 refrigerant, leaves us with the very high cost of repair with little to no assurance or guarantee that the customer will get adequate life from the rest of the system. We can only warranty the parts installed; everything else is old, worn out, and will have no warranty or guar