Diagnosed cracked heat exchanger. System is 3 years old, parts covered by warranty, customer pays labor


Corey B.

Corey B. Job Checkin

Service Call Platinum Client replaced failed contactor, verified refrigerant pressures 120/290. blower capacitor and dual capacitor both failed. customer declined capacitors.

Service Call Platinum Client

replaced failed contactor, verified refrigerant pressures 120/290. blower capacitor and dual capacitor both failed. customer declined capacitors.

Corey B.

Corey B. Job Checkin

AC Service


James S.

James S. Job Checkin

Duct Modifications made to HVAC system include : adding a 10x10 in the master bedroom and flexing it back to the return drop

Duct Modifications made to HVAC system include : adding a 10x10 in the master bedroom and flexing it back to the return drop

Don M.

Don M. Job Checkin


Matthew G.

Matthew G. Job Checkin

Performed Platinum Comfort Club Membership Tune-Up on Heating System (2) 2014 York split systems using 14x25x1 and 16x20x1 filters. Both 70 percenter flue vents and cooling off of r410a refrigerant. Also present is mini split system. Performed Platinum Comfort Club Membership Tune-Up on Cooling System

Performed Platinum Comfort Club Membership Tune-Up on Heating System (2) 2014 York split systems using 14x25x1 and 16x20x1 filters. Both 70 percenter flue vents and cooling off of r410a refrigerant. Also present is mini split system.

Performed Platinum Comfort Club Membership Tune-Up on Cooling System

John B.

John B. Job Checkin

Service Call Fee: refrigerant pressure looks good(125/305). Blower wheel has some build up on it but evaporator coil looks clean. Evaporator coil is an N coil, removed metal plate on right side that may have been hampering airflow through the coil. Also found several return grates upstairs that have been obstructed. Informed customer to keep return air area clear to prevent poor airflow of the system. I recommend an air cleaner and maintenance for the system.

Service Call Fee: refrigerant pressure looks good(125/305). Blower wheel has some build up on it but evaporator coil looks clean. Evaporator coil is an N coil, removed metal plate on right side that may have been hampering airflow through the coil. Also found several return grates upstairs that have been obstructed. Informed customer to keep return air area clear to prevent poor airflow of the system. I recommend an air cleaner and maintenance for the system.

Corey B.

Corey B. Job Checkin

Performed Platinum Comfort Club Membership Tune-Up on Cooling System found AA 501 filter to be clogged. this likely caused Evaporator coil to freeze in cooling this preventing system from keeping up. signed customer up on cozy plus maintenance plan, performed cooling check, found capacitor to be failed and replaced it, replaced AA 501 filter, found thermostat wire to outdoor unit to be damaged with bare copper showing. recommended replacing entire run of thermostat wire from indoor unit to outdoor unit. customer declined at this time. recommended installing surge protector for AC to protect system from potential surge.

Performed Platinum Comfort Club Membership Tune-Up on Cooling System

found AA 501 filter to be clogged. this likely caused Evaporator coil to freeze in cooling this preventing system from keeping up. signed customer up on cozy plus maintenance plan, performed cooling check, found capacitor to be failed and replaced it, replaced AA 501 filter, found thermostat wire to outdoor unit to be damaged with bare copper showing. recommended replacing entire run of thermostat wire from indoor unit to outdoor unit. customer declined at this time. 

recommended installing surge protector for AC to protect system from potential surge.

Corey B.

Corey B. Job Checkin


Corey B.

Corey B. Job Checkin


Corey B.

Corey B. Job Checkin

since blower is not starting every time and when it does the furnace limits out in only a few minutes, customer is not going to run it. has woodstove as backup. would like estimate to replace. scheduled for comfort advisor to provide estimate this evening.

since blower is not starting every time and when it does the furnace limits out in only a few minutes, customer is not going to run it. has woodstove as backup. would like estimate to replace. scheduled for comfort advisor to provide estimate this evening.

Kyle P.

Kyle P. Job Checkin

Service Call Platinum Client did find blower capacitor to be failed , replaced cap and did notify since the cap was dead that very likely the blower motor is going to fail soon as well . motor pulling elevated amps.

Service Call Platinum Client did find blower capacitor to be failed , replaced cap and did notify since the cap was dead that very likely the blower motor is going to fail soon as well . motor pulling elevated amps.

Doug H.

Doug H. Job Checkin

Maintenance Check

Maintenance Check

Corey B.

Corey B. Job Checkin

installed warranty control board. verified normal operation.

installed warranty control board. verified normal operation.

Don M.

Don M. Job Checkin

PROVIDED CUSTOMER WITH HVAC ESTIMATE