Rated 5.0 out of 5 stars based on 4 customer reviews

Inspection of AC System

James is very professional, knowledgeable, and friendly. He did a thorough inspection and would recommend him for anyone looking for someone that knows his trade. Thank you Hot2Cold for sending out such a skilled technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super James comes through

James Thornsberry was able to solve a problem with our heating system that no one else was able to. He spent about 2 hours going over every wire and connection making sure everything was correct. We now have heat. Thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and quick resolution of the problem

Hot 2 Cold continues to impress! They respond quickly and resolve the issues in a timely manner. Best ac company in Tampa.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Emergency call due to ceiling collapse

My wife and I were wakened by a loud crash about 2:30am. At first I thought one of our grandkids had fallen out of bed. I jumped out of bed and ran to their room only to find that the ceiling in the hallway had collapsed. Dripping water was soaking the carpet. I went into the attic to find that the drain pan under the air handler was filled with water. Using a sponge I was able to soak up about 6 gallons of water to stop the dripping. I called Hot 2 Cold and spoke to an operator who make an appointment for later in the morning. John Campbell arrived at about 10:30am. I showed him the hole in the ceiling and explained that Hot 2 Cold technicians had installed the drain pan about 2 month ago. It was apparently mounted so that it drained away from the water sensor so that the AC continued to run even though the drain pan was over flowing. John re-leveled the pan and flushed the drain line so we were good to go. He also arranged with his Service Manager for the ceiling to be repaired since it was Hot 2 Cold's mistake that caused the problem. I was very happy with Johns thoroughness and professionalism, but not happy that the previous technician caused the problem in the first place. There was no charge for the service call.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for odessa, fl

rodney@hot2coldairconditioning.com

rodney@hot2coldairconditioning.com Job Checkin

Annual Maintenance and Filter Changes

Annual Maintenance and Filter Changes

troy@hot2coldairconditioning.com

troy@hot2coldairconditioning.com Job Checkin

Provided estimates for customer

Provided estimates for customer

Corey B.

Corey B. Job Checkin

Do you give humidification is up and running all it was was the reminder on the thermostat that killed it

Do you give humidification is up and running all it was was the reminder on the thermostat that killed it

Warren G.

Warren G. Job Checkin

- Replacement of the blower motor/module - Replacement of the blower control board

- Replacement of the blower motor/module
- Replacement of the blower control board

Brennan  G.

Brennan G. Job Checkin

Brennan G Today I visited for an inspection of crimped copper pipes inside the attic ( a tree branch had fallen through the roof and damaged the copper lines that were suspected to be refrigerant lines). I found that the lines were only for the condensate drain pumps, I tested one the the pumps and it still functions normally. I did not have to quote any repairs. I recommended having a through inspection and maintenance preformed on the ac systems.


Brennan  G.

Brennan G. Job Checkin

Brennan G Today we visited to preform a maintenance on both systems Both systems are clean and all electrical components are within specs Chemical flushed both drains Found the goodman condenser was dirty and covered in grass trimmings. Rinsed outdoor coil. Both systems refrigerant levels are within spec 20* split. Noticed neither of the system have any air purification , besides the uv lamps inside the cabinets. Discussed installing whole home air purifiers to increase indoor air quality.

Brennan G
Today we visited to preform a maintenance on both systems
Both systems are clean and all electrical components are within specs
Chemical flushed both drains 
Found the goodman condenser was dirty and covered in grass trimmings.
Rinsed outdoor coil.
Both systems refrigerant levels are within spec 20* split.
Noticed neither of the system have any air purification , besides the uv lamps inside the cabinets.
Discussed installing whole home air purifiers to increase indoor air quality.

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Repair Option performed maintenance santi duct blower ok drainline flushed comp ok fan ok cap ok charge ok system up and running

Repair Option performed maintenance santi duct blower ok drainline flushed comp ok fan ok cap ok charge ok system up and running

Brennan  G.

Brennan G. Job Checkin

Brennan G Todays visit was for the system not cooling. Preformed diagnosis and inspections, found that the breaker was tripped , caused by a faulty compressor fan dual capacitor. Replaced the faulty component and installed a compressor saver with a surge protector to help prevent this from happening in the future. Vacuumed the drain and washed condenser coil as a courtesy System is cooling at this time

Brennan G
Todays visit was for the system not cooling.
Preformed diagnosis and inspections, found that the breaker was tripped , caused by a faulty compressor fan dual capacitor.
Replaced the faulty component and installed a compressor saver with a surge protector to help prevent this from happening in the future.
Vacuumed the drain and washed condenser coil as a courtesy 
System is cooling at this time

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Repair Option installed filter 21x21x5

Repair Option installed filter 21x21x5

Brennan  G.

Brennan G. Job Checkin

Brennan G Today I returned with a factory condenser fan motor and fan blade Replaced components and also installed a new capacitor Informed client that the repairs preformed have a 1 year warranty Condenser fan motor and blade Contactor Capacitor System is cooling at this time

Brennan G
Today I returned with a factory condenser fan motor and fan blade 
Replaced components and also installed a new capacitor
Informed client that the repairs preformed have a 1 year warranty 
Condenser fan motor and blade 
Contactor 
Capacitor 
System is cooling at this time

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Brennan g Upon arrival determined that the outdoor fan blade is bad. Tried to find replacement part at various supply houses, unable to find a match up. Ordered the new parts from Lennox , should be in tomorrow afternoon I will return and replace the condenser fan motor and blade with the oem parts from Lennox. Remaining work to be done as a courtesy.

Brennan g
Upon arrival determined that the outdoor fan blade is bad.
Tried to find replacement part at various supply houses, unable to find a match up.
Ordered the new parts from Lennox , should be in tomorrow afternoon 
I will return and replace the condenser fan motor and blade with the oem parts from Lennox.
Remaining work to be done as a courtesy.

Brennan  G.

Brennan G. Job Checkin

Brennan G Todays visit was for the system not cooling. Before arrival the system had started working again. Client reported the outside fan had stopped working but the compressor was still running. Found that the motor we had installed in November is the wrong horsepower. Also the contactor relay is burned up. Scheduled repair for tommorow , we will replace the condenser fan motor under warranty. The contactor is not under warranty, both new components will have a 1 year warranty. Informed client the system is very old and regular breakdowns with become more frequent , suggested replacing the equipment

Brennan G
Todays visit was for the system not cooling.
Before arrival the system had started working again.
Client reported the outside fan had stopped working but the compressor was still running.
Found that the motor we had installed in November is the wrong horsepower.
Also the contactor relay is burned up.
Scheduled repair for tommorow , we will replace the condenser fan motor under warranty.
The contactor is not under warranty, both new components will have a 1 year warranty.
Informed client the system is very old and regular breakdowns with become more frequent , suggested replacing the equipment

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

1 Time Maintenance blower ok drain line flushed comp ok fan ok cap ok charge ok system working properly

1 Time Maintenance blower ok drain line flushed comp ok fan ok cap ok charge ok system working properly

Luis@hot2coldairconditioning.com

Luis@hot2coldairconditioning.com Job Checkin

Maintenance was completed all electrical components and capacitor are working normal. I have replace filter in every single units. 2 filter 20x22 one inch 1 20x20 1 inch

Maintenance was completed all electrical components and capacitor are working normal. I have replace filter in every single units. 2 filter 20x22 one inch 
1 20x20 1 inch

Tony L.

Tony L. Job Checkin

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System.<br> <br> Completed,customer concerned drain not draining,checked temperatures and sub cooling on both systems,and both systems checked good.recommended maintenance for both and gave estimates.