Local Reviews
for seminole, fl


Job Locations
for seminole, fl

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Called customer

Called customer

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Customer had a few questions about ductwork and some dust that was coming out of his vent

Customer had a few questions about ductwork and some dust that was coming out of his vent

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Customer had to sub because the drain line clogged. Investigation Troy found that the drain line is very short, so we lengthen it a little bit to see if we could draft out some condensate and eliminate the atmospheric trapping that seems to be happening.

Customer had to sub because the drain line clogged. Investigation Troy found that the drain line is very short, so we lengthen it a little bit to see if we could draft out some condensate and eliminate the atmospheric trapping that seems to be happening.

Corey B.

Corey B. Job Checkin

Freon

Freon

troy@hot2coldairconditioning.com

troy@hot2coldairconditioning.com Job Checkin

Yearly maintenance

Yearly maintenance

troy@hot2coldairconditioning.com

troy@hot2coldairconditioning.com Job Checkin

Provided estimates for new system

Provided estimates for new system

Corey B.

Corey B. Job Checkin

Inverter technology delivers the most efficient and comfortable home available. This machine is like having dozens differently sized AC units! It utilizes a variable speed compressor, variable speed outdoor fan, and variable speed indoor blower to continuously throttle the exact amount of cooling power required. The unit monitors outdoor temperature, indoor temperature, and the desired temperature while using a learning algorithm to deliver peak efficiency and humidity control.

Inverter technology delivers the most efficient and comfortable home available. This machine is like having dozens differently sized AC units! It utilizes a variable speed compressor, variable speed outdoor fan, and variable speed indoor blower to continuously throttle the exact amount of cooling power required. The unit monitors outdoor temperature, indoor temperature, and the desired temperature while using a learning algorithm to deliver peak efficiency and humidity control.

Berry D.

Berry D. Job Checkin

System consult with James Thornsberry condenser has shit the bed compressor and inverter board

System consult with James Thornsberry condenser has shit the bed compressor and inverter board

Corey B.

Corey B. Job Checkin

Lizard, fried to capacitor

Lizard, fried to capacitor

Corey B.

Corey B. Job Checkin

Found no current issues with the unit. Checked drain line, pressures, and capacitor. The system appear to be fully operational at this time. There is a bit of drywall dust on the evaporator coils that may be lowering the vapor saturation, however the unit is functioning properly.


Geraldo R.

Geraldo R. Job Checkin

During diagnostic fault led has displayed both input overcurrent and thermistor or voltage/current sensor abnormality. Going to need to contact tech support.

During diagnostic fault led has displayed both input overcurrent and thermistor or voltage/current sensor abnormality. Going to need to contact tech support.

Corey B.

Corey B. Job Checkin

Found unit short cycling, with the pressures skyrocketing as if the unit is overcharged. Compressor locked out during the time of service. Possible faulty reversing valve not engaging properly, however unsure what the true 410a levels are. Will discuss with office for possible solutions.

Found unit short cycling, with the pressures skyrocketing as if the unit is overcharged. Compressor locked out during the time of service. Possible faulty reversing valve not engaging properly, however unsure what the true 410a levels are. Will discuss with office for possible solutions.

Geraldo R.

Geraldo R. Job Checkin

Performed first year free annual maintenance. Not properly scheduled. Sprayed down evaporator coil and drain. Washed condenser coils off. Checked motor amp draws to be within specs. Reset filter reminder on thermostat.

Performed first year free annual maintenance. Not properly scheduled. Sprayed down evaporator coil and drain. Washed condenser coils off. Checked motor amp draws to be within specs. Reset filter reminder on thermostat.

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Repair Option maintenance was done today santi duct drain line flushed comp ok blower ok cap ok fan ok charge ok system works in heat and cooling system is up and running

Repair Option maintenance was done today santi duct drain line flushed comp ok blower ok cap ok fan ok charge ok  system works in heat and cooling system is up and running

Corey B.

Corey B. Job Checkin

1 Time Maintenance perform found clogged drain line and dirty filter FILTER MUST BE REPLACED 20x25x4.5 is needed flushed drain line and checked all system operation system up and running

1 Time Maintenance perform found clogged drain line and dirty filter FILTER MUST BE REPLACED 20x25x4.5 is needed flushed drain line and checked all system operation system up and running