Matt did an excellent job explaining the benefits, pros and cons to getting my issues taken care of .
I have had alot of maintenance programs where I felt they were a waste of money, Larry is the first tech that actually spent time to explain everything on how my system works and what maintenance he did on unit. He is very pleasant, professional and honest. I would recommend this tech to anyone.
Diag Found blower motor bad bearings Also outdoor unit has compressor issues Replacing unit Rheem 3 ton heat pump closet 14,764 service finance Install 2/15 Kevin Braskamp 916-603-9130
Customer quest heating inspection service performed heating inspection service removed inspected and cleaned flame sensor adjusted gas pressure inspected ductwork and found system operates properly. Customer has 3cooling and 2 heating tune ups left see previous invoice sep24-2020
Performed heat maintenance. Heat rise is within specs, filter is clean, flushed drain line. Amp draws are ok, refrigerant pressures are within specs. Cleaned outdoor coil. System is operational at this time. No club opp, still have AC visit left.
Performed heat maintenance. Filter is clean, heat rise is within specs, amp draws are ok, refrigerant pressures are within specs. Tightened and checked all wires. Contactor has burn marks. Flushed drain line, system is operational at this time. No club opp, has AC visit still.
Gave homeowner an estimate for a 1 ton mini split cut in. Homeowner will be getting other estimate.
Ducting to back room is improperly ran. Has 8†feeding 2 8†ducts in master bedroom. 12†duct coming off end of plenum needs to be moved to side or top of plenum. Should be at least a 10†at minimum feeding 2 8â€. Whole house fan will work in attic. Blow in another R19 of cellulose To bring to R38.
Replaced evap coil under parts warranty. Pulled a vacuum on system and charged unit to proper levels. System operations ok at this time.
Upon arrival set system to cool. System ran for 30 seconds then turned off. Checked all electrical. Electrical is fine. Checked pressures. System is very low on refrigerant and making system cut out on low pressure. Performed electronic leak test and found leak on evaporator coil. Homeowner approved ordering new coil and refrigerant to fill system after coil is replaced. Homeowner opted to not charge up system today. Coil will be deliver to shop to tomorrow. Office will schedule follow up to install new coil at earliest appointment available. System is operational but still not cooling
Installed hot surface igniter and tested heating system operations. System operating properly for 20 minutes and no other issues occurred.
When I arrived collected ladder that was left from install. Unable to change hot surface igniter due to part being damaged, will need to order and come back to replace at a later date.
COLEMAN - Removed and properly dispose of existing gas/electric unit, provide and install new 4.ton gas/electric singe stage split down-flow in closet, flushing existing drain/refrigerant lines, connecting to existing drain/refrigerant lines, ducting, grilles/registers, propane kit, Honeywell t-6 thermostat, a/c pad, disconnect /whip, installation includes equipment, material, basic seal and taxes. Excludes permits. COLEMAN 14 SEER 4-TON MOBILE HOME CONDENSER/COIL CONDENSER M# TW4B4821S COIL M# MHSR4HXXFLX1 10 YEAR PARTS/2 YEAR LABOR (excludes permit (mobile home permit add 10% using separate "Mobile Home Permit" Task) COLEMAN 4 Ton DF 80% Mobile Home Furnace M# DGAA090BDTD 2 YEAR PARTS AND LABOR/10 YEAR HEAT EXCHANGER (excludes permit (mobile home permit add 10% using separate "Mobile Home Permit" Task) Total installation: 8,100 Method of payment: Service Finance Company Llc Approval number: 2661987 Install date: 9-4-20
Went through ductwork and found issues with the installation to back bedroom and one 12†off end of plenum. Will set appt to return and install whf, insulate and redo a couple of ducts. Financing through Sychrony 18 months interest free.
Upon arrival homeowner stated she had an electrician out to do work. After he left whole house fan no longer work. Unit has no power. Homeowner will need a electrician to come out and figure out where the loss of power is at.
Performed a tuneup on a rheem ac system. All checks are within manufacture specifications and the system is operational at this time.
Per A tuneup on a Lennox ac system. All checks are within manufacture specifications and the system is operational at this time.