Lorenzo M.

Lorenzo M. Job Checkin

Neutralizer stone 1 Gas Hot Water Boiler: Triangle Tube High efficiency Boiler - Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners tubes and heat exchanger- ok, vacuumed-ok Check and clean flame sensor/flame rod and ignition Assembly-ok Spark igniter. Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Exhaust-ok Check Temperatures & Water pressure settings; 15psi Performance-ok Check and run Thermostats- operating well at this time. Check zoning operation-isolate and run zoning. Check Honeywell zone valves ok amps and voltage check. Check water feeder, low water cut off, and expansion tank. Check for water leak no leakage at this moment. Run and monitored for good operations. All zones are fine supply and return lines getting hot. Perform check for indirect HWH. Check for water leak, no leakage at this time. Check c


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-12BA499F65D34C35AA03B343EC79D1E2 Perform maintenance on Mitsubishi dual zone heat pump for the second floor bedroom and office and Trane furnace With April air steam humidifier, and UV light kit: MITSUBISHI DUCTLESS: * removed front cover of air handler * Remove the air filters * Remove turning vanes * open grates to access blower cabinets * chemically sprayed washed and rinsed, evaporator coils, clean, and clear * flushed/ Tested drain lines and primary pans * Chemically treated primary pans * Secured and inspected electrical connections * Washed air filters, clean and clear * Reassemble indoor heads and polished all equipment * Call for heating and remotes and test system operations * Check airflow and temperature splits at indoor heads- okay * chemically sprayed and rinsed outdoor condenser coil, cabinet and fan blades clean and clear GAS FURNACE: * shut power to furnace * customer just recently


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-12BA499F65D34C35AA03B343EC79D1E2 Perform maintenance on Mitsubishi dual zone heat pump for the second floor bedroom and office and Trane furnace With April air steam humidifier, and UV light kit: MITSUBISHI DUCTLESS: * removed front cover of air handler * Remove the air filters * Remove turning vanes * open grates to access blower cabinets * chemically sprayed washed and rinsed, evaporator coils, clean, and clear * flushed/ Tested drain lines and primary pans * Chemically treated primary pans * Secured and inspected electrical connections * Washed air filters, clean and clear * Reassemble indoor heads and polished all equipment * Call for heating and remotes and test system operations * Check airflow and temperature splits at indoor heads- okay * chemically sprayed and rinsed outdoor condenser coil, cabinet and fan blades clean and clear GAS FURNACE: * shut power to furnace * customer just recently


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-851069D0CA694C36956360E15583CC6C


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-0013-17B53D51748F4F738B63BDB3D4A5D02D Customer has a water leak from the second floor air handler in the attic- He states at arrival that he has been emptying the overflow pan weekly: • At arrival, there is a small amount of water in the overflow pan • Check the trap and drain line on the system- The trap is bone dry with absolutely no water inside • Open the air handler cabinet up • Found the primary drain pan completely cracked- Water is not holding inside of the pan • Someone tried a temporary repair of adding silicone to the primary pan, but it is not holding • Also, the pitch of the drain line is incorrect and needs to be redone • The air handler is not level or pitched properly to the drain, causing water to drain slowly and the pan to hold lots of water • All findings were shown and explained to the customer It is recommended that the second floor primary pan be replaced, the drain line re-don


Gary P.

Gary P. Job Checkin

**Upon arrival met with customer who’s explaining his situation. Customer systems are operating normally. Customer has issue with airflow for daughter’s room. Where room is getting too cold when the AC runs in the summer or too hot during heating season. **Customer system is free flow. Furnace & Coil system in the basement that service a few rooms in the basement and 2nd floor. **Customer tried to close registers in the basement to improve airflow for other part of the second floor. Closing grill did not improve airflow quality in office area on 2nd floor. **Customer also been trying to address this issue by adjusting both 1st floor and 2nd floor yo-yo thermostat. **Advised customer on insulation options or Additional install of hvac system for 2nd floor that would help assist with his imbalance of airflow. Customer has a lot of bay windows throughout the home. **Customer is inquiring if it’s possible to insulate just daughter room or to have attic insulated. Regular or spray foamed. A


Mark E.

Mark E. Job Checkin

Heating tune up

Heating tune up