9320 S. Pole Rd
Oklahoma City, OK 73160
(405) 794-8900

Our Top Cities


Job Locations
for mcloud, ok


Map of McLoud OK
Sam J.

Sam J.


Job Checkin

Sam J - arrive to Red club member for a summer service on a split Coleman system. Customer greeted me at the gate and we began discussing the system in any issues he has experienced. No issues to report prior to the service so I began by testing the thermostat operation. Replaced 2 filters at the indoor unit. Cycled off power to the condensing unit so that I could check the capacitor and clean the condenser coil. Removed the shroud to clean coil as it was a microfin coil. Capacitor was within 10% of its microfarads value, for the condenser fan motor and compressor, 42.9/5.0mfd of 45/5mfd rating. Checked compressor and fan motor amperage during start up and operation, compressor was running 5.4 A., fan motor was running 0.9 A. Moved to the indoor unit while condensing unit dried. Found weak capacitor on the blower motor and the customer approved replacing it which I did with new 7.5mfd capacitor. Then checked the evaporator coil, which was clean and free of any corrosion, w