9320 S. Pole Rd
Oklahoma City, OK 73160
(405) 794-8900

Our Top Cities


Job Locations
for newalla, ok


Map of Newalla OK
Kianoosh M.

Kianoosh M.


Job Checkin

Blue Shield protection plan member, AC tuneup on heat pump and air handler system. Spoke with homeowner, and wife would like to have the bedroom vents adjusted as there is about a 3° difference from the temperature in the bedroom to the temperature in the hall, where the thermostat is. Talked about doing an air balance analysis versus a quick damper adjustment. The air analysis would include adjusting all dampers to give even flow and takes a little bit more time. Adjusting the damper for the bedroom can be done with today’s tuneup at no extra cost. Homeowner agreed to have adjustment done with today’s tuneup. Homeowner blows out washable filters with air compressor and they are in good shape. Checked initial master bedroom supply vent airflow at 565 FPM and 386 FPM respectively. Went to attic and checked dampers adjusted dampers open for runs that were mostly closed. This more evenly distributed the airflow throughout the system. Checked supply vents in master bedroom again and got 43