Temperature rise across condenser in ac mode = 53 deg inlet 67 deg outlet on a 54 deg day = 14 deg temperature rise. Compressor amps = 13.2/17.9max Condenser fan amps = 1.29/1.50max Condenser fan velocity = 1800 Run time 30 min. Temperature rise across condenser in heatpump mode = 53 deg inlet 45 deg outlet on a 54 deg day = 8 deg temperature drop. Compressor amps = 12.7/17.9max Condenser fan amps = 1.22/1.50max Condenser fan velocity = 1800 Run time 30 min. Return air temp = 74. supply air temp = 95. temperature rise on heat pump alone = 21 deg. Heat strip #1 amp = 20.5 Heat strip #2 amp = 20.7 Heat strip #3 amp = 21.3 Blower motor amp = 2.3/6.9 Return air temp = 75. Supply air temp = 115. Temperature rise on emergency heat alone is 40 deg. Master bedroom velocity 340. Pink room velocity 780.