Alex was marvelous...on time and work completed quickly...
Found defective parts leaking from our previous repair. Replaced the leaking parts with new parts. No other leaks found after repairs this time.
Tech arrived and found system not running, customer worked on system stated he put new capacitor for fan on. Tech found disconnect was flipped the wrong way tech corrected and system is now running and cooling properly. Fan amps were high tech recommend replacing motor customer is going to take care of it himself.
Pulled tank and replaced tank to boul seal and bolts.
Found clog in 1 1/2 galvanized pipe advice home own It willl need be replaced
Checked hose bib for leak under house. It is not leaking and I recommended they have the window checked for leaks….window has gaps around the top.
Tech found dual run 70/5 capacitor had failed on compressor side fan side is 4.7 slightly weak. Tech called Justin and informed him on findings he approved replacement with turbo capacitor. Once replaced system started up no issues tech did inform Justin if he had maintenance plan he did not he wants quote on maintenance plan as well. They have 2 straight ac splits and 2 gas furnace
UNIT #7, KITCHEN- 4 TON TRANE SPLIT HEAT PUMP
Tech found system pressure were at 52/198 for r22. Tech performed leak search got hits on bottom side of evaporator coil. Compressor ohmed good at this time. Due to age and type od Freon te h recommend replacing system. S#yg2v
PERFORMED CMA FULL SERVICE ON 10 SPLIT SYSTEMS. SPLIT SYSTEM #1 AIR HANDLERS EVAPORATOR COIL WAS FROZEN ON ARRIVAL, PUT SYSTEMS BLOWER ON TO THAW OUT COIL . TECH CHECKED DELTA T WHICH IS TEMPERATURE DIFFERENCE BETWEEN RETURN AND SUPPLY AND IT WAS 10 DEGREES. DELTA T IS LOW WOULD RECOMMEND FOR IT TO BE AT LEAST 17 DEGREES DIFFERENCE. WILL HAVE TO ADD MORE REFRIGERANT IN UNIT TO SEE IF THAT WAS THE ISSUE. SPLIT SYSTEM #2 COMPRESSOR CAPACITOR RATED FOR 70mf TESTED WEAK AT 66.2mf. CAPACITOR DUE FOR FAILURE. RECOMMEND REPLACEMENT OF CAPACITOR. SPLIT SYSTEM #4 CONDENSER UNITS DUAL RUN CAPACITOR RATED FOR 45/5mf TESTED AT 38.9/5.01mf. TESTED WEAK ON 45{COMPRESSOR SIDE). CAPACITOR DUE FOR FAILURE. RECOMMEND REPLACEMENT OF CAPACITOR. REPLACEMENT OF DUAL RUN CAPACITOR FOR SPLIT SYSTEM #4 SPLIT SYSTEM #7 WAS TURNED OFF UPON ARRIVAL, MULTIPLE I
Customer just had shoulder surgery and was baby sitting grand daughter. Just wanted pricing emailed to her.
Tech performed ESA on 1 system. Gas Pack- tech serviced and cleaned system found indoor evaporator coil leaking refrigerant, compressor ohming bad and duct work under sized and in poor condition. Field supervisor out to verify challenges.
System 4 - Compressor Replacement. Tech pulled vacuum on system and charged with 5lbs and 7oz of R410A, factory charge is 8lbs. Rewired compressor wires and reconnected all other wiring. Will need to return to further diagnose low voltage short due to it blowing low volt fuse as soon as power was turned on. OD Disconnect had 2- 15amp blown fuses, replaced with 2- 30amp for the time being but will need 2- 15 fuses(small ones). Tech finished up charging the system with 3lbs of 410a refrigerant. and corrected the low voltage challenge. Short at the Reversing valve wire was identified. System #4 is back cooling. 30amp fuses at the outdoor unit will be needed to be replaced with 15amp fuses(small fuses).
Tech performed ESA on R22/propane gas pack. Found no challenges with unit despite age. Heating and cooling correctly. Ductwork is in the same poor condition as last visit. Tech recommends duct replacement. Customer will consider replacing ductwork at the same time as new unit if she needs to replace unit. Not now. Tech recommended extending ESA. Customer extended on MSA. May call in to switch to yearly.
Tech preformed CMA INSPECTION on 10 Split Systems. System #7 is down from previous diagnosis and due to multiple challenges tech recommended replacing unit. System #4 condenser is down due to compressor being shorted to ground, compressor wiring harness being melted and blown fuses in disconnect. Unit is approximately 3-4 years old so tech has estimate created for replacing compressor that will be attached to invoice. Also tech contacted office to set up a quote for replacing entire system to give customer options. All other systems are operating at this time. Tech has attached system performance reports to invoice along with pictures.
Replaced 8kw heat strip kit on AH#1(system #1). Tech had to cut the plugs and straight wire it by using wire nuts.