Ralphie was on time , very nice and did a great job ! Thank you Ralphie !!! Recommend Kings electric without reservation . Only reservation is it is over priced compared to the competition .
Ralphie has been here before. He is professional kind and very knowledgeable He should be given a raise !!
Your representative Ralphie should be commended for his professionalism and expertise. We were so pleased
We were called out for a warranty. The receptacles I added to the office is not receiving the proper voltage. This issue is do to the amount of computers on one circuit. I'm recommending we install a new circuit from the electrical room to the new office space.
We were called out due to flickering computer in the conference room. I found a loose neutral in the back of the Junction box above the ceiling. **warranty **
We were called out to the office where I spoke to Britney. We are installing 2 additional receptacles to the conference using the existing circuit.
I continued with the alumi-con installation. I need 1 more day
I replaced the main panel today and completed 2 bedrooms (alumi-con)
We need to replace the interior and exterior panel. The house also has aluminum wires and need alumi-con splicers.
I was called out because water was leaking from the air handler. What I found was a clogged drain and a stuck float switch. I cleared the drain line and cleaned the float switch. But I'm recommending a new float switch be installed.
We had to add some freon. But I believe the airflow on the return side of the system. The door in the hallway restrict the flow of air.
During my evaluation I found an open neutral on the circuit that feeds the refrigerator and countertop receptacles. I also found aluminum wire and coper wire in the same wire nut. This is what may have cause the wire nut in the panel to melt. I'm recommending we install alumi-con splicers throughout the house.
We installed two light fixtures in the bathroom.
We are replacing the board in the heat pump
We are to install Alumiconn connectors in each device and the electrical panel.
I found a loose connection in the fixture power wires causing flickering lights
Replace parking lot lights, diagnosis of the perimeter recessed light fixtures.
Replace 5 parking lot light fixtures on existing 12 ft light pole and convert the 2 light fixture at floor height to LED