Thank you for choosing Kings Electric and air conditioning! This estimate includes: - Diagnose & repair (2) outlets not working.
Fixed a/c leak by vacuuming drain line
Relocate three (3) strip fixtures per USDA requirements. Provide six (6) plastic tube sleeves on lamps.
Relocate three (3) strip fixtures per USDA requirements. Provide six (6) plastic tube sleeves on lamps.
LM to call us for additional details
Replace two (2) receptacles with GFCI receptacles. Troubleshoot / repair issue with Emergency Exit Light Fixture.
Dear customer. We’re happy to give you the estimate to — Supply and install (4) GFCI outlets in bathrooms and 6’ of sink — Supply and install (1) disconnect for the tankless water heater — Rewire and label (2) emergency and exit lights to comply with the code — Supply and install (3) blank covers at panel A Thank you for choosing us and feel free to reach out for more details **********Jason - Kings Electric & AC**********
Relocate and extend existing 3-phase circuits at hood area to new location for meat cutting machines. Adjust wire size, circuit breaker and conduit / cables to accommodate new machines at 3-phase, 20-amps. Eliminate two (2) existing 3-phase receptacles along with the wiring from the stove area. Reuse the space in the existing panel for the new machines. Covert three (3) existing single phase, 240-volt receptacles to 3-phase, 240-volt, 20-amp receptacles in the same location. Note: Existing panel may not be large enough to handle the additional loads. Kings will not be responsible for overloads. Permits are not included. Me & Phil demoed 2 circuits and identifide Pulled out wires too panel ran 3 phase home runs , identifying circuits.. Installed breakers. And outlets Job is complete
Hello Rosemarie! Today we came out and did an electrical inspection on your home. Upon further investigation we noticed that a lot of the receptacles within the home are ready to be changed. Because of this we highly recommend that you do a device upgrade throughout your whole home. This includes swapping out all outlet and switches for new high grade ones. We also noticed that in your bathroom and kitchen there are a couple of receptacles that need to be converted to GFCI protected ones. Another thing we noticed was that In your panel you have uneven voltage readings. A phase reads about 118v and b phase is reading near 116v which is lower than the recommended average. Please contact FPL to check that their side is providing the proper voltage to your home and if still there is no change consider changing out the main breaker that is feeding the indoor panel. Thank your for trusting in us today and we look forward to servicing you in the near future. Your Service Electrician Je
Job # SHMNP123A58B2-1 Approval # PHM 0725171 Supply and install new 150A indoor electrical panel. Panel is extremely old and needs to be replaced. Old breakers and connections are causing power issues inside home. Supply and install outdoor 150A main breaker panel. Main breaker panel is a very old brand and is losing its strength from years of use.
Replace (1) 125 amps main lug indoor panel Pull permit and get inspection
Evaporator coil frozen causing water dripping on the floor. Freon was low (80 psi on low side). Added 2 lbs 410A to get it run temporary. Need installation team come back to check for the leaks