Dear customer We’re here today to give you the estimate to repair electrical problems that addressed on inspection report — Replace (3) GFCI outlets in kitchen and (1) in hall bathroom — Rewire kitchen light (above the sink) circuit has been wired to the load side of GFCI outlet — Supply and install (1) blank cover for garage electrical box — Repair neutral - hot reverse wires at master bathroom outlet — Repair exposed romex wiring in master bathroom sink cabinet by installing protected sleeve — Remove garage ceiling fan due to safety and cap-off electrical wiring — Repair garage romex wiring exposed by run the wires inside the conduit, (2) wall lights need to be removed and reinstalled. Replace (1) 4 ton AC compressor out of warranty