John G.

John G. Job Checkin

Did a diagnostic found wires loose in j box and whip half way out. Tighten wires and secured whip., Titghened it up. Installed new pull chain for ceiling fan light switch…


John G.

John G. Job Checkin

Hey Timothy! Thank you for calling Kings electric & a/c for your electrical upgrades. Today I was able to finish installing your grounding system for your home, and I also added the surge protector as well. Finally the light in the patio was installed and the dimmer for it too. Everything is working 100% once again. If you have any questions or concerns, please reach out. Your electrical technician, Xavier


Nick G.

Nick G. Job Checkin

Fasten existing HIHAT back into ceiling


Nick G.

Nick G. Job Checkin

1)——Replace 100 amp main breaker service panels and 100 amp indoor circuit panels. 2)——Update grounding system.


Nick G.

Nick G. Job Checkin

INSTALL TIMER FOR PATH LIGHTS


Nick G.

Nick G. Job Checkin

1)——Troubleshoot fountain pump circuit,landscape/front yard wall sconce lighting circuit and car port sconce path lighting circuit. A)install customer supplied pump and connect to existing switch. C)Install customer supplied low voltage transformer and feeder wire for lighting circuit. D)remove and replace customer supplied switch and outlet in carport. 2)——Remove and replace 3 customer supplied sconce path lights by carport. 3)——Remove and replace 1 customer supplied sconce light in front yard.


Nick G.

Nick G. Job Checkin

1)——Upon review of 4 point inspection notes we found that they noted cloth wiring at panel and in attic. 2)——From an Electricians’s stand point this wiring is not considered “cloth wiring”. The wire noted has a cloth jacket with rubber insulated wire, which is totally safe and up to code. Cloth wiring has a cloth jacket and cloth insulated wire which is not safe because the cloth insulation over time gets hard and cracks and falls off the wire leaving it bare and exposed in some spots. RECAP: Their was no cloth wiring in the system and all wiring is safe and up to code.


Nick G.

Nick G. Job Checkin

Extend circuit from existing smoke detector locations into each bedroom for a total of 4 circuit extensions. Install proper junction box at each location. Supply and install 7 hardwired and interconnected carbon/smoke detector combos with 10 year lithium battery backup.


Nick G.

Nick G. Job Checkin

1)-----Troubleshoot water heater: All connections are tight and voltage is correct. The reset button for water heater thermostat was tripped which is an indication that there is an internal problem with water heater. We reset switch and it held for now. We turned the temperature down to 100 degrees to see if it holds. Water is hot as of now. If it trips again water heater should be replaced.


Jason  B.

Jason B. Job Checkin

Replace (1) customer supplied ballast


Nick G.

Nick G. Job Checkin

1)-----Remove 1 dimmer switch for living room track lights and 1 for master bathroom lighting. 2)-----Replace with new dimmer switches.


Nick G.

Nick G. Job Checkin

1)-----Extend circuit from exisitng switch line to desired location of chandelier. 2)-----Install fan rated fixture box. 3)-----Assmeble and install customer supplied chandelier. 4)-----Remove exisitng dimmer and replace with customer supplied dimmer.


Jason  B.

Jason B. Job Checkin

Diagnosis and repair Add 3-6 lbs R22


Jason  B.

Jason B. Job Checkin

Diagnosis and repair Add 3-6 lbs R22


Jason  B.

Jason B. Job Checkin

Replace (1) 50 fuse at disconnect box