Job Locations
for wilton manors, fl

John G.

John G. Job Checkin

Diagnose / Troubleshoot issue electrical panels


John G.

John G. Job Checkin

Determined meters were switched when they were replaced by Florida Power & Light # 3 had # 20's Meter Bills were reversed Unit # 20's meter was reconnected by F.P.L.


John G.

John G. Job Checkin

Determined meters were switched when they were replaced by Florida Power & Light # 3 had # 20's Meter Bills were reversed Unit # 20's meter was reconnected by F.P.L.


John G.

John G. Job Checkin

Thank you for choosing Kings Electric and air conditioning! This estimate includes: - removing low voltage wire going through dryer vent cover. - Reconnect with wire nuts. - Check if panel is live and in good condition.


John G.

John G. Job Checkin

Estimate sent


John G.

John G. Job Checkin

Customer would like two lights installed in front of home. Need switch leg.


John G.

John G. Job Checkin

Supply and install new outdoor 125A rated electrical panel.


John G.

John G. Job Checkin

Did a diagnostic found wires loose in j box and whip half way out. Tighten wires and secured whip., Titghened it up. Installed new pull chain for ceiling fan light switch…


John G.

John G. Job Checkin

Hey Timothy! Thank you for calling Kings electric & a/c for your electrical upgrades. Today I was able to finish installing your grounding system for your home, and I also added the surge protector as well. Finally the light in the patio was installed and the dimmer for it too. Everything is working 100% once again. If you have any questions or concerns, please reach out. Your electrical technician, Xavier


Nick G.

Nick G. Job Checkin

Fasten existing HIHAT back into ceiling


Nick G.

Nick G. Job Checkin

1)——Replace 100 amp main breaker service panels and 100 amp indoor circuit panels. 2)——Update grounding system.


Nick G.

Nick G. Job Checkin

INSTALL TIMER FOR PATH LIGHTS


Nick G.

Nick G. Job Checkin

1)——Troubleshoot fountain pump circuit,landscape/front yard wall sconce lighting circuit and car port sconce path lighting circuit. A)install customer supplied pump and connect to existing switch. C)Install customer supplied low voltage transformer and feeder wire for lighting circuit. D)remove and replace customer supplied switch and outlet in carport. 2)——Remove and replace 3 customer supplied sconce path lights by carport. 3)——Remove and replace 1 customer supplied sconce light in front yard.


Nick G.

Nick G. Job Checkin

1)——Upon review of 4 point inspection notes we found that they noted cloth wiring at panel and in attic. 2)——From an Electricians’s stand point this wiring is not considered “cloth wiring”. The wire noted has a cloth jacket with rubber insulated wire, which is totally safe and up to code. Cloth wiring has a cloth jacket and cloth insulated wire which is not safe because the cloth insulation over time gets hard and cracks and falls off the wire leaving it bare and exposed in some spots. RECAP: Their was no cloth wiring in the system and all wiring is safe and up to code.


Nick G.

Nick G. Job Checkin

Extend circuit from existing smoke detector locations into each bedroom for a total of 4 circuit extensions. Install proper junction box at each location. Supply and install 7 hardwired and interconnected carbon/smoke detector combos with 10 year lithium battery backup.