Ralphie P.

Ralphie P. Job Checkin

We disconnect wire to old post light, because it was causing the gfci in the garage. We also tightened the loose receptacle above the counter top. Door bell needs a new diode because the one that's installed is broken.


John G.

John G. Job Checkin

Came out as a record breaker was tripping. We came out to inspect the system we upgraded a 50 amp breaker to a 60 amp breaker so the water heater can run out at maximum capacity water heater is no longer tripping 30+ minutes on. AC system we unclog the drain‘s filled with water system is running at 74°. Hey system and water heater are not interconnected nor on the same breaker


Ralphie P.

Ralphie P. Job Checkin

We are supplying and replacing three 1x4 fixtures with led 1x4 fixtures


Ralphie P.

Ralphie P. Job Checkin

We installed the plug and cord for the Range


Ralphie P.

Ralphie P. Job Checkin

We are to install customer supplied cabinet light.


Ralphie P.

Ralphie P. Job Checkin

I replaced a bad dimmer in the kitchen


Ralphie P.

Ralphie P. Job Checkin

The equipment is receiving power but it will not turn on. I believe the ups system in faulty. I bypassed the ups system so the office can work temporarily. And we supplied a surge strip to connect all the equipment.


Ralphie P.

Ralphie P. Job Checkin

The equipment is receiving power but it will not turn on. I believe the ups system in faulty. I bypassed the ups system so the office can work temporarily. And we supplied a surge strip to connect all the equipment.


Ralphie P.

Ralphie P. Job Checkin

We are relocating four switches. We are Adding three receptacles. One for the gas stove and two for the cabinet lights.


Ralphie P.

Ralphie P. Job Checkin

I found a short in the outside receptacle next to the ac unit.


Ralphie P.

Ralphie P. Job Checkin

Diagnosed light switch.


Ralphie P.

Ralphie P. Job Checkin

We replaced melted wires feeding