Ramon O.

Ramon O.


Job Checkin

Came out here for an AC maintenance. Upon arrival tested static pressure. Static pressure was failing while taking the temperature split and noticed that there was no difference between the return and the supplier so I went outside to make sure that the compressor was running seen at the fan itself was running hooked up my gauges to the suction liquid line. Notice at the pressures or stagnant to both of them were the same gave me the conclusion that the compressor wasn’t running itself. Make sure there was getting voltage which it was. I also made sure the capacitor was working capacitor was reading perfectly with the specifications condone that the compressor itself was done for, customer requested to have supervisor out to give a quote on replacing compressor or a new system