Found unit low on refrigerant due to leaking Schrader valve. With customer approval I replaced both Schrader valves and filled system up with refrigerant. System held pressures and had an 18 degree temp split t departure. I sprayed unit down since it was really clogged. Ac running at departure.
System is frozen up had fan running to thaw out. Will revisit tomorrow morning to check on cause for. Since system is fully frozen. Did clean out drain line for the mean time and added towels to help electrical components from getting wet.
Arrived to replace failed blower motor. Upon replacement, temperature split and refrigerant levels were in range. System cooling correctly upon departure. -Ren
Arrived for no cool. Found refrigerant lines and evaporator coil frozen. Furnace control board showing a blower motor issue. Scheduled a time to replace blower motor -Ren
AC System Repairs: Investigating cooling issues, I discovered a clogged evaporator coil hindering the AC system's efficiency. To address this, I meticulously cleaned the coil, promoting better heat exchange within the system and enhancing cooling efficiency. This meticulous repair ensures consistent and reliable cooling for the homeowner.