Went for a maintenance call today. Did a static pressure test, it passed. Tested the heat kit it passed. Blower motor amperage passed, but blower wheel is dirty. Ducts are also very dirty. Temperature split between the supply and return ducts passed. UV light is out, bulb needs replaced. Thank you for choosing LBA services!
Completed heating inspection for customer. Tested air handler and heat pump, heat pump functions normally and operates a 30-40 degree temp split, tested electric back up heat all coils energize and producing 50+degree air. All aspects test within manufacturer specs, no recommendations at this time.
Went in for a service call today. After hooking up the gauges I noticed that the suction side was low and that the discharge side was high. So I perceived that there was a restriction in the system. So I replaced the filter dryer inside the ac unit and cleaned the piston metering device. After refilling the system with refrigerant the system passed on superheat. The system was working properly when we finished. Thank you for choosing LBA Services!
Went for a service call today. Customer mentioned the house wasn’t cooling well. When checking pressures, I noticed the super heat was really high and the suction side was low. After doing a few tests, I figured out that the piston is clogged, going to replace filter dryer as well. Thank you for choosing LBA services!
8/19/2024 Today we returned to do install on an expansion tank and a small sprinkler line repair function restored to both. Vitals: -Water Quality: failed -Water heater: good After reviewing the entire house I went over everything with Clint to ensure they understood everything going on in the house and what could be done to address it. (Getting supervisor out?) Services done today: -install new expansion tank -small sprinkler line repair Thank you for choosing LBA Services Your technician, Addison
DATE 8/16/2024 Tested water quality and pressure. Looked at a leaking pvc line, and a water heater. Going back Monday to fix the sprinkler line and install new expansion tank Vitals: -Total Dissolved Solids: 223 -Water Pressure Static: 60 -Water Pressure Faucet Open: 53 -Water Temp Setting: -Water Temp Output: -Water Hardness: 5 -Water Quality: ph 8; chlorine 2 -Water Heater: -Water Lines: -Drain Lines: Wear and Tear: Failed expansion tank, leaking pvc line for irrigation. After reviewing the entire house I went over everything with Clint to ensure they understood everything going on in the house and what could be done to address it. (Getting supervisor out?) Solutions: Replace expansion tank. Remove & replace leaking pvc Services done today. Inspection and diagnosis Thank you for choosing LBA Services Your technician, Addison
Chuck’s main floor and upstairs unit both have much less airflow from the ductwork than is required for their cooling needs. Decreased the fan speeds in both units to temporarily relieve the excessive air pressure. Return visit scheduled for next Wednesday to review the findings and team up for solutions on the systems.
Completed AC inspection, all aspect of system test within manufacturer specifications. System operating normally upon departure.
Completed AC inspection for customer. Customer has two systems, one supplying air to the main floor and basement and one dedicated for the second floor. First floor system tested within manufacturer specifications. Second system is low on refrigerant but is R22, customer rarely uses system, no additional refrigerant added. Noted that inducer motor for second system was tight to the spin, advised customer to check prior to use to ensure its functioning properly.