Went for furnace inspections today. One furnace has a serious airflow issue and a carbon monoxide leak. Other furnace passed safety inspection and airflow. Inducer motor and blower motor amperage passed. Temperature split between the supply and return duct passed. Gas pressure and pressure switch passed. Thank you for choosing LBA services!
Arrived at customers for the furnace tuneup process of the inspection we discovered a dirty blower wheel along with receiving a high calling static pressure, dirty filter. All other components met within factory specs.
Had a service call customer said house wasn’t cooling, it was blowing heat. Checked the capacitor first it was bad. Replaced it, system is now cooling. Thank you for choosing LBA services!