Patrick  K.

Patrick K.


Job Checkin

Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Found that the system is operating with failing static pressure. Reached out to a field supervisor to finish the diagnosis on the systems static pressure. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Found excessive debris built up on the fan for heating and cooling. Checked systems heat exchanger to ensure proper venting of flue gas. Found hot spots and rust on the heat exchanger. Found that the heat exchanger has hot spots present. With all the dust found on the fan checked the duct and found significant amounts of dust present. Spoke with homeowner about the system. Furnace is operational at this time.