450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Local Reviews
for mineral, va

Rated 5.0 out of 5 stars based on 40 customer reviews

Excellent service

Couldn’t have ask for better service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding

Outstanding from James as usual!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

We have been using Loving Air for years now and have always been pleased with their service. They are prompt to the appointment; they are very respectful of our property; and their work is thorough. Their customer service is also excellent.

  • Overall Experience
  • Quality
  • Price
  • Convenience

HVAC Service Call

Jeremy went right to work diagnosing the problem with our heat pump. The circuit board was our issue and would need to be ordered. Very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Follow-up service call

Great service visit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

James is the best, outstanding tehnician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

He did a good job explaining everything to us

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

James Morris is the best serviceman we have ever had. We are requesting that when ever we require service in the future that we get James. Just a joy to work with. Bill and Martha Blessing

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing service

Trey came by today for a routine check up of the HVAC system and did a damn good job. He fixed what needed to be fixed and kept me informed of what was going on.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

So so very polite and done a great job. Thanks James

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service at a affordable price.

Loving Air is always on time, our technician James always greets us with a smile and is polite. Their prices are affordable for the level of service provided. I would highly recommend Loving Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for mineral, va

Jeremy S.

Jeremy S. Job Checkin

All wiring is tight and in good condition. I found the inducer collector box drain line leaking into the furnace. I received permission and rebuilt a portion of the line so it could drain properly. The heat exchangers are in good condition. No refrigerant leaks found at this time. The refrigerant pressures are in correct range per manufacturer specifications. I completed our check sheets for the systems. The systems are working properly at this time.


Mark D.

Mark D. Job Checkin

Preformed maintenance inspection on main house heat pump. Checked indoor coil and found it to be clean. Preformed leak search on coil and didn't find any leaks at this time. Checked blower motor amp draw and found it to meet manufacturer set points. Checked outdoor coil and cleaned it per contract, didn't find any leaks at this time. Checked compressor and outdoor fan motor amp draw and found them to meet manufacturer set points. Checked pressures with gauges and found them to meet manufacturer set points with current outdoor temperature. Preformed maintenance on basement heat pump. Checked indoor coil and found it to be clean. Preformed leak search on coil and didn't find any leaks at this time. Wiped down blower motor wheel per contract. Checked blower motor amp draw and found them to meet manufacturer set points. Checked outdoor coil and found it to be clean with no signs of leaks at this time. Checked compressor and outdoor fan motor amp draw and found them to meet manufactur


Jeremy S.

Jeremy S. Job Checkin

All wiring is tight and in good condition. No refrigerant leaks found at this time. All motor amps are in correct range per manufacturer specifications. I flushed the condensate drain lines. The refrigerant pressures are in correct range per manufacturer specifications. I completed our check sheets for the systems. The systems are working properly at this time.


Mike  M.

Mike M. Job Checkin

Arrived to the customers home and greeted him at the door. Spoke to the customer about how the systems have been performing and I’ve had any concerns at this time. Completed maintenance inspection of heat pump and mini split systems with cleaning per membership. Completed maintenance inspection, checklist for heat pump system uploaded pictures and videos Collected customers payment for maintenance renewal and return system to service


Mike  M.

Mike M. Job Checkin

Route to the customers home and greeted family member inside. Spoke to the customer about how systems been performing and if they had any questions or concerns before starting. Completed maintenance inspection of Infiniti heat pump. Completed maintenance inspection checklist uploaded pictures and videos. Addressed all concerns with family member and owner of the property. Customer declined all repairs today. Not interested in moving forward at this time. Returned to service


Mike  M.

Mike M. Job Checkin

I arrived to the customers home and greeted her at the door. Spoke with the customer on how the systems been performing. I’ve had any concerns at this time. Customer showed me main systems thermostat saying auxiliary heat was running at 50° outdoor temp. Completed today’s maintenance inspection on both systems. Maintenance inspection, checklist uploaded pictures and videos. Address concerns with customer with main level system found failed low pressure switch causing outdoor unit not to run allowing auxiliary heat to operate. Quoted customer for a labor only repair customer would like to verify the JB labor warranty is expired paperwork shows 02/16/24 as the expiration date. Emailed customer incomplete estimate until office can verify for customer and send updated estimate. Returned to service


Trey M.

Trey M. Job Checkin

During my inspection today, the customer greeted me at the front door. They allowed me to come inside and they showed me around to all the equipment. They showed me the air filter(s). They were 2 16 by 16. They then showed me the thermostat. It was mercury thermostat. They then showed me the indoor unit and the outdoor unit. I got started by turning the system off at the thermostat and made my way to the air handler. I inspected multiple different components on the system, including the blower wheel/motor(clean), evaporator coil(clean), drain line (vacuumed, drain from the outside), ductwork(slightly dusty,), electrical connections/components, etc. I checked all of these components for proper operation and cleanliness. As well as to make sure that nothing was damaged. I made my way to the outdoor unit. On the outdoor unit I inspected multiple different components as well, including electrical connections/components, Condenser fan motor, Compressor, Motor amp draws, Refrigerant pre


Trey M.

Trey M. Job Checkin

During my inspection today, the customer greeted me at the front door. They allowed me to come inside and they showed me around to all the equipment. They showed me the air filters. They were 2-14x14,20 x 20. They then showed me the thermostat. They were Honeywell Nonprogrammable. They then showed me the indoor units and the outdoor units. (Attic) I got started by turning the system off at the thermostat and made my way to the air handler. I inspected multiple different components on the system, including the blower wheel/motor, evaporator coil, drain line, ductwork, electrical connections/components, etc. I checked all of these components for proper operation and cleanliness. As well as to make sure that nothing was damaged. I made my way to the outdoor unit. On the outdoor unit I inspected multiple different components as well, including electrical connections/components, Condenser fan motor, Compressor, Motor amp draws, Refrigerant pressures(good), And the outdoor unit coil. Oth


Trey M.

Trey M. Job Checkin

During my inspection today, the customer greeted me at the front door. They allowed me to come inside and they showed me around to all the equipment. They showed me the air filter(s). It was a 2-14 x 20. They then showed me the thermostat. It was a trane programmable. They then showed me the indoor unit and the outdoor unit. I got started by turning the system off at the thermostat and made my way to the air handler. I inspected multiple different components on the system, including the blower wheel/motor, evaporator coil, drain line, ductwork, electrical connections/components, etc. I checked all of these components for proper operation and cleanliness. As well as to make sure that nothing was damaged. I made my way to the outdoor unit. On the outdoor unit I inspected multiple different components as well, including electrical connections/components, Condenser fan motor, Compressor, Motor amp draws, Refrigerant pressures(good), And the outdoor unit coil. Other technical informati


Mark D.

Mark D. Job Checkin

Preformed heating inspection on heat pump system. Checked indoor coil and cleaned it per contract. Preformed leak search on coil and didn't find any leaks at this time. Wiped down blower motor wheel per contract. Checked blower motor capacitor and found it to meet manufacturer set points. Checked blower motor amp draw and found it to meet manufacturer set points. Checked outdoor coil and found it to be clean with no signs of leaks at this time. Checked outdoor capacitor and found it to meet manufacturer set points. Checked outdoor compressor and fan motor amp draw and found it to meet manufacturer set points. Checked pressures with gauges and found them to meet manufacturer set points with current outdoor temperature. Preformed heating inspection on heat pump system. Checked indoor coil and cleaned it per contract. Preformed leak search on coil and didn't find any leaks at this time. Wiped down blower motor wheel per contract. Checked blower motor amp draw and found it to meet manu


Mark D.

Mark D. Job Checkin

To replace crawl space indoor and main unit capacitors together 7.5 mfd and 45-7.5 mfd. 3 years warranty on parts. Preformed heating inspection on dual fuel system. Checked indoor and found it to be clean. Preformed leak search on coil and didn't find any leaks at this time. Wiped down blower motor wheel per contract. Checked blower motor capacitor and found it to meet manufacturer set points. Cleaned flame sensor per contract. Checked heat exchanger and didn't find any holes or cracks at this time. Checked outdoor coil and found it to be clean with no signs of leaks at this time. Checked outdoor capacitor and it failed my inspection. Checked outdoor compressor and fan motor amp draw and found it to meet manufacturer set points. Checked pressures with gauges and found them to meet manufacturer set points with current outdoor temperature. Preformed heating inspection on dual fuel system. Checked indoor and found it to be clean. Preformed leak search on coil and didn't find any leak


Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by the customer and was led to the thermostat and it is functioning properly at this time. Inspected 20x25x2 media filter and it is clean at this time. Tape and ductwork joints are tight and neat at this time and without any visible air leaks at this time. Refrigerant lines are tight and neat and Arma flex insulation is tight and neat and without any visible defects at this time.inspected condensate drain and it is clear at this time. Ez trap safety switch is functioning properly at this time. Inspected CS1 safety switch attached to secondary drain port and it is functioning properly at this time. Inspected condensate pump and it is functioning properly and it’s discarding water from tank properly at this time. Inspected evaporator coil and it is clean on top and bottom at this time. Electrical connections are tight and neat to the components at this time. Wire nut connections are tight and neat without any visible defects or issues at


Chris B.

Chris B. Job Checkin

Customer showed location of thermostat explained how he would get alerts saying uv light needed to be changed. System has humidifier no uv lights on the system. Initially put system in heat due to home being 67 degrees. Found kink in drain line on humidifier which had tear fixed line. Blower motor is clean amping within manufacturer specifications at this time. Coil is clean free of leaks at this time. When going to the outdoor unit found the coil clean free of debri. Inspected electrical connections on the system which were free of damage. Capacitor was in correct range along with system charge. Customer declined options at this time returned system to normal operation.


Mark D.

Mark D. Job Checkin

Preformed heating inspection on LP furnace. Checked evaporator coil and found it to be clean. Preformed leak search on coil and didn't find any leaks at this time. Wiped down blower motor wheel per contract. Checked board for any error codes and found none. Checked flame rod and found it needs to be replaced. Checked heat exchanger and didn't find any holes or cracks. Checked blower motor amp draw and found it to meet manufacturer set points. Preformed heating inspection on LP furnace. Checked evaporator coil and found it to be clean. Preformed leak search on coil and didn't find any leaks at this time. Wiped down blower motor wheel per contract. Checked board for any error codes and found none. Checked flame rod and cleanedit per contract. Checked heat exchanger and didn't find any holes or cracks. Checked blower motor amp draw and found it to meet manufacturer set points


Chris B.

Chris B. Job Checkin

Upon arrival customer showed location of thermostats and systems located in the basement. Found basement filter clean free of debri. Inspected amps which were in correct range at this time. Blower motor clean free of debris at this time. Gas connections are secure no leaks. Found Photomaxs operating properly at this time. Coil is clean free of debri at this time no leaks detected at this time. Inspected drain line which was clean and clear at this time. When looking at the main level furnace filter was clean free of debris at this time. Gas connections secured properly at this time. Inspected reme halo which is operating properly at this time. Gas pressure is within manufacturer specifications at this time. Blower motor is clean free of debris at this time. Ez trap clean clear of debris at this time. Customer declined options at this time returned system to normal operation.