450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for woodford, va


Map of Woodford VA
Chris B.

Chris B.


Job Checkin

Upon arrival customer stated how system wasn’t coming on. When looking at the crawlspace air handler found the blower motor failed inspection starting for second then cutting back out. The motor does have debris build up on it when inspecting the coil it was clean and free of debris. Inspected condensate pump which was working properly at this time. Inspected the capacitor for the condenser fan and compressor which both were in correct range. Provided customer with options to address issues which they approved. 7/7 Upon arrival greeted customer then began removing the blower motor from the system in the crawlspace. Once the new one was put into place and powered system began operating. When looking at the charge of the system it about a pound low. 140/299 with line temp of 92. Customer approved for charging system pressure at 130/322 line temp 92 10 degree sub cooling.