9 Executive Park Drive, Suite 100
Billerica, MA 01862
781-396-5279

Local Reviews

Rated 5.0 out of 5 stars based on 3 customer reviews

Great work by the plumbers!

I recently had a full conversion from Oil to Gas done by the plumbers at Medford Wellington and they did a tremendous job. Mario and Max ran new piping that looks great and is out of the way and got everything up and running in a timely manner. The new burner on our Steam Furnace looks and works great! Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional service and good results

Found the company easy to work with and quite accommodating, though more expensive than others

  • Overall Experience
  • Quality
  • Price
  • Convenience

highly informative technician

Ray was efficient, informed and informative about our odd heating system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

James A.

James A. Job Checkin

Commercial Plumbing repair for a leaking pipe. Found the pipe has a rust hole. Removed the corroded segment of the pipe and the system is no longer leaking.


Dan  R.

Dan R. Job Checkin

Commercial Refrigeration repair for a Trane RTU that is not cooling the space. tested the operation of the unit and found the compressor to have failed. Replaced the compressor and the system is fully operational.


Sandra  L.

Sandra L. Job Checkin

Commercial Refrigeration Repair for a Carrier RTU that is not cooling the space. tested the system and found the Compressor to have failed. replaced the compressor and the system is fully operational.


Philip R.

Philip R. Job Checkin

Commercial HVAC Repair for a Lennox RTU that is not cooling the space. Found the System locked out high head pressure. Checked the coils and filters and found the 100% plugged. Chemically cleaned the coils and replaced the Filters and the system is fully operational.


Ryan W.

Ryan W. Job Checkin

Commercial Heating repair for a Carrier RTU that is not heating the space. tested the operation of the system and found the gas valve to have failed. Replaced the gas valve and the system is fully operational.


Patrick H.

Patrick H. Job Checkin

Commercial heating repair for a Trane Heat pump that is not heating the space. Gained access to the villa. Found space at 63 degrees. Tstat calling for heat. Supply temp only at 71 degrees. Inspected unit and found heat pump running but no electric heat. Inspected the thermostat and found no call to aux heat terminal. Replaced thermostat with a new one from maintenance. Started unit and checked operation. Electric heat now functioning properly. Checked out with mod. Job complete.


Lori M.

Lori M. Job Checkin

Commercial Refrigeration repair for a Traulsen Ice Machine that is not making any ice. I opened the cupboard to the ice machine I could see the thickness probe caught in the curtain down the bottom. This made it so the curtain would not close and the sensor believed the unit to be in the continuous harvest. Replaced sensor back in its original position and watch three batches of ice drop before I left


James A.

James A. Job Checkin

Commercial Electrical Repair for a tripping GFCI Checked power at the POS receptacles behind the main bar. Found no power at the device. GFCI breaker was tripped. Reset breaker and the system is fully operational.


Scott  F.

Scott F. Job Checkin

Commercial Refrigeration repair for a Bohn walk-in cooler that is not cooling the space. Tested the operation of the system and found the system low on refrigerant. Leak checked the system and repaired the leak. recharged the system and the system is fully operational.


Ronald  D.

Ronald D. Job Checkin

Commercial Refrigeration Repair for a Hoshizaki ice machine that is not cooling the space. Found the Evaporator fan motor to have failed. Replaced the evaporator fan motor and the system is fully operational.


Dave  R.

Dave R. Job Checkin

Commercial HVAC Repair for a Trane RTU that is not cooling the space. Found the system completely plugged and in need of replacement. Replaced the Filters and the system is fully operational.


Paul A.

Paul A. Job Checkin

Commercial HVAC Repair for a Carrier RTU that is not cooling the space. tested the operation of the system and found the Indoor Blower motor to have failed. Recommended Commercial HVAC Install for a new Indoor Blower motor.


Brian  C.

Brian C. Job Checkin

Commercial Plumbing repair for a Bryant boiler that is leaking. Found the black steel pipe coming out of the tank to have cracked at the weld. repaired the broken weld and the system is fully operational.


Brian  C.

Brian C. Job Checkin

Commercial heating install for a gas valve for a Lennox RTU that is not heating the space. Removed and replaced the faulty gas valve. Started up and tested operation. The unit is fully operational.


John  H.

John H. Job Checkin

Commercial Refrigeration repair for a Hoshizaki Ice machine that is not making any ice. Found the machine locked out on long harvest, found both thumb screws for water distribution assembly were MIA, and assembly had fallen out. ice thickness sensor against the evaporator. Set assembly in place and reset unit replaced the screws to hold everything in place and the Ice Machine is fully operational