Unit was freezing up due to lack of air flow on evaporator coil. Noticed there was a blanket of hair & dirt stopping the coil from pushing airflow efficiently. Pulled the hair in a solid piece & the unit is cooling properly now. Checked pressures after to ensure there would be nothing else wrong but pressures/temperatures looked good. No other issues to report.
Disconnect was burned up at condenser , swapped it out, heater is running now. No other issues to report.
Found a bad capacitor on the fan. Replace 10 MFD capacitor check cooling cycle Delta t is it 20° degreesF, Fahrenheit. Checked all motor amps all sounds OK. Fan was a little high, but nothing too address at this point.
Replace blower assembly vacuum cabinet Completed informed customer there is no warranty on repair
The unit was frozen when I got here defrosted the unit and found it was low on refrigerant. We went over there options with the unit and they decided to add leak stop. Added that and refrigerant and everything looks good to go signed up for the membership and don’t need to complete the maintenance