1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews
for claymont, de

Rated 5.0 out of 5 stars based on 7 customer reviews

Great Service and Rep!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful Service

Always a great experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful

Clay identified the problem quickly and gave me a great tutorial to keep it from happening agIn

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always a lovely visit

Craig is wonderful.. at this point he's a friend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, friendly,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service, very informative!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for claymont, de

Amanda S.

Amanda S. Job Checkin

Furnace Repair: Responding to a call regarding a malfunctioning furnace, our dedicated team arrived at the client's residence. A thorough inspection revealed a faulty ignition system as the cause of the issue. Swift and precise repairs were conducted, restoring the furnace's operation and providing the homeowner with much-needed warmth during the chilly night.


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

Upon arrival thermostat was saying 70 and set to 70. I ran system through a cycle. Raised setpoint to74 system reached and thermostat was satisfied. Checked exhaust removal system factory specs .40amps actual .43 amps flame safety was 2.8. had a heat rise of 37 degrees filter was ok. All electrical wiring and connectors are tight and secured.


Clay K.

Clay K. Job Checkin

No heat gas warm air, checked system and found that the indoor control system had failed, exhaust removal system running without a call for heat, installed replacement and test ran in heat, fan on and cooling, operation normal at this point.


Amanda S.

Amanda S. Job Checkin

Electrical Repairs: Upon receiving a service request related to constant tripping of circuit breakers in a client's home, our experienced electrical team conducted a meticulous diagnosis. The investigation identified overloaded circuits and a faulty outlet as the root causes. To address the issue, we expertly redistributed electrical loads, alleviating the strain on circuits, and replaced the defective outlet. Our skilled technicians performed a complete assessment of the entire electrical system, offering recommendations for improvements to enhance safety and prevent future disruptions. The homeowner now benefits from a seamlessly functioning electrical setup, ensuring uninterrupted power for their residence.


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

See previous invoice


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

Club rejuvenation cleaning cleaned and wiped down all indoor wall units. Took all filters out and washed check heating operation checked air movement system, checked all wiring connection indoor and out outdoor coils where clean did find a dirty and rocks behind outdoor unit covering lower half of coil on outdoor, needs to be removed away from outdoor units. System are functioning as intended at this time


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

2611 we don't have access to via property management company (Pabian Properties)


Greg H.

Greg H. Job Checkin

Test ran units in heat and ac 1st floor unit found drain should be cleaned customer is apart of the club plan recommend having cleanings down before next summer


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

WO-TNFR220334 replaced a section of exhaust removal system tested ran system


Greg H.

Greg H. Job Checkin

Filter recently changed by homeowner. Blower and evaporator are clean no leaks wiped down unit eletracal connections are tight. Voltage enhancement system read within factory spec heat exchanger has no areas of concern at this time draft motor and blower amps are within factory spec eletracal connections are tight Checked drain operation normal at this time


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

Performed club rejuvenation cleaning, 16X20X1 media air ranger filter isn't the correct type filter. Checked humidifier Aprilaire 600 series pad is clean. Exhaust removal system factory specs 0.50 amps actual 0.23amps exhaust removal voltage enhancement system factory specs 5uf actual 4.91uf hot surface igniter has 0.51amps clean flame sensor. Air movement has a ECM motor,blower wheel is clean. Found exhaust piping leaking at fitting joint. Needs to be cut out and replaced. Burner tubs has concerns of rust. Heat exchanger has some rust system. System has a heat rise of 52 degrees


Greg H.

Greg H. Job Checkin

Wiped down furnace. Lubed draft motor cleaned up rust from collector box leaking by slightly, recommend replacing collection system. Tested drain with a gallon of water eletracal connections are tight.. wiped down and removed rust from gas line. Checked blower and evaporator coil they are clean. Both filters were recently changed and look fine. Getting A 50 degree heatrise testing operation is normal at this time


Clay K.

Clay K. Job Checkin

Condensate removal pipe had come off the fitting and was in the ground, repair and test with water.


Kyle H.

Kyle H. Job Checkin

WO-TNFR179204 replaced drain pan, reconnected exhausted and fresh air piping, brazed copper back into coil, leaked checked, pulled vacuum, repiped 3/4 drain line PVC cleaned out condensate pump collector system is functioning as intended


Kyle H.

Kyle H. Job Checkin

Found a faulty drain pan, and a clogged 3\4 PVC drain line. Used the wet vac to clean up water at the bottom of the furnace. Will need to order drain pan and replace 3\4 schedule 40 PVC drain line