1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews
for abingdon, md

Rated 5.0 out of 5 stars based on 5 customer reviews

Excellent Service

Our technician Koz, did a great job ,and was very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Technician was very nice and informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable and professional

Representatives was polite and on time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

The best. As always!!!

Great team that does an excellent job with fantastic customer service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for abingdon, md

Amanda S.

Amanda S. Job Checkin

Air Conditioning System Repair: Swiftly responding to a reported decrease in the AC unit's performance, our skilled technician conducted a thorough assessment to identify the underlying issue. The diagnostic process revealed a damaged condenser coil as the root cause of the reduced efficiency. Acting swiftly and decisively, we replaced the compromised coil with a high-quality replacement, ensuring optimal functionality. This meticulous repair not only restored the system's cooling efficiency but also contributed to the overall performance and longevity of the air conditioning unit. As a result, the client now enjoys enhanced indoor comfort, maintaining an optimal and refreshing climate within their living space.


Amanda S.

Amanda S. Job Checkin

Plumbing Repair Service: Upon arrival at a client's residence with reported slow drains, our skilled technician utilized a powerful drain auger to clear a stubborn clog deep within the plumbing system. The advanced equipment ensured a thorough removal of the obstruction, restoring optimal water flow and preventing future clogs. To provide the client with peace of mind, a camera inspection was conducted to confirm that the entire drain was free from obstructions. This meticulous approach not only addressed the immediate slow drain issue but also provided the client with a preventive measure against potential future plumbing problems. The client can now enjoy efficient plumbing performance and a worry-free drainage system, thanks to our comprehensive and proactive plumbing repair service.


Jack W.

Jack W. Job Checkin

Heat pump cleaning: heat rise was 46. Air filter system was clean and recently changed out by customer. Air movement system was very clean and also clear of all debris. All wiring was clean and clear of all debris. Drain line was clean and clear of all debris. Voltage enhancement system was running at 44.6/4.9uf. Factory spec is a 45/5uf. Voltage gateway system was clean and clear of all debris and signs of concern. Cleaned off inside and outside of indoor unit with proper cleaner and wipes. System was up and running at normal operation at the end of the visit.


Jack W.

Jack W. Job Checkin

Furnace cleaning: heat rise was 68. Air filter system was clean and recently changed by customer. Air movement system was clean and clear of all debris but I wiped down just to make sure. All wiring was clean and secure. Drain line was clean and clear of all debris and signs of concern. Flame gateway system was clean and clear of all debris and signs of concern. Flame sensor system was clean and clear of all debris and signs of concern. Cleaned off inside and outside of indoor unit with proper cleaner and wipes. System was up and running at normal operation at the end of the visit. Coil=good Heat movement=good Comp.=good Static pressure=good testing at 0.47


Amanda S.

Amanda S. Job Checkin

Air Conditioning Service. As part of our routine service, we provided thorough maintenance for a client's A/C system. We meticulously cleaned and inspected the unit, fine-tuned its performance, and identified potential issues before they became major problems, ensuring your A/C's longevity and efficient operation.


Jack W.

Jack W. Job Checkin

AC club rejuvenation: Delta T was 20. Air filter system was clean and recently changed out by customer. Air movement system was clean and clear of all debris and signs of concern. All wiring was clean and secure. Drain line system was clean and clear of all debris and signs of concern. Voltage enhancement system was running at 44.7/4.8uf. factory spec is a 45/5uf. Voltage gateway system was clean and clear of all debris and signs of concern or worry. Cleaned off inside and outside of outdoor unit. System was up and running at normal operation at the end of the visit with no signs of concern.


Greg H.

Greg H. Job Checkin

Upon arrival found gfi tripped for airhandler no problems found at this time if it happens again recommend replacing it. Also gave estimate for dryervent cleaning, duct cleaning, and water heater.


Tammy A.

Tammy A. Job Checkin

customer is signing up for the gold club plan with amanda will pay in full today


kozemchakmoonservices@gmail.com

kozemchakmoonservices@gmail.com Job Checkin

Attic system has a Delta T of 22 degrees. Changed air filter with customer supplied filter. Air circulation system is dirty. Brushed off air circulation system. Electrical connections are tight. Indoor voltage enhancement system reads 20uf actual is 19.5uf and is within factory spec. Installed treatment in water removal system. Flushed water removal system with cleaner. Purged water removal system. Outdoor and indoor heat transfer system is clean. RLA and FLA are within factory spec. Outdoor voltage enhancement system reads 35/5uf actual is 35.8/4.9 and is within spec. WD40 wipedown on the indoor and outdoor system. First floor outdoor system RLA and FLA are within factory spec. Outdoor voltage enhancement system reads 40/5uf actual is 40/4.8 and is within spec. Indoor system has a Delta T of 21 degrees. Moisture restoration system is clean. Brushed off air circulation system. Changed filter with customer supplied filter. Electrical connections are tight. Exhaust


kozemchakmoonservices@gmail.com

kozemchakmoonservices@gmail.com Job Checkin

Supply temp is 49 degrees with a return of 70 degrees. Delta T is 21 degrees. Air filter is clean. Air circulation system is clean. Tightened electrical connections on T-Stat port on the electronic control system. Air circulation voltage enhancement system has a factory spec of 10uf and reads 9.5uf and is within the allowable fault. Leak searched indoor heat transfer system and found no leaks. Water removal system is clean. Inspected combustion chamber with camera and found no areas of concern. Air circulation system is reading 7.45 amps. Wd40 wipedown on the indoor system. Outdoor heat transfer system is clean. RLA and FLA are within factory spec. Outdoor voltage enhancement system has a factory spec of 45/7.5 uf and reads 42.3/4.5 and is out of factory spec. Voltage enhancement system should be replaced.


Kyle H.

Kyle H. Job Checkin

See first Invoice


Kyle H.

Kyle H. Job Checkin

Attic Rejuvenation: Supply temperature was 109 and the return temperature was 71. Heat rise had a temperature difference of 38 degrees. Checked filter which was dirty so I changed out with customers extras. Checked air movement system which was clean and clear of all debris with no signs of concern. Checked all wiring inside electrical compartment which were all clean and secure. Checked all tubing which was clean and clear of all debris. Checked heat sensor system which was dirty so I cleaned with proper tool. Checked flame gateway system which was clean and clear of all debris with no signs of concern. Checked heat movement system which was clean and clear of all debris with no signs of concern. System was up and running at normal operation at the end of the cleaning<br> <br> <br> Basement Rejuvenation: Supply temperature was 107 and the return temperature was 67. Heat rise had a temperature difference of 40 degrees. Checked filter which was dirty so I changed out with customers extr


Kyle H.

Kyle H. Job Checkin

WO-TNFR105476. Replaced basic combustion and flame safety system.


Kyle H.

Kyle H. Job Checkin

Club Furnace Rejuvenation: supply temperature is 110 degrees with a return temperature of 68 degrees. Heat rise is 42 degrees. Air movement system is clean. Air filter is dirty. Indoor voltage enhancement system has a factory spec 10uf and is reading 9.7mfd and is within allowable fault. Checked electrical connections and are tight. Checked tubing and is good. Cleaned off flame safety system. Tested gas supply shut off valve and is working properly. Safety switch is working properly. Igntion system is reading 17 ohms and should be reading between 30-60 ohms. Recommend having a new ignition system put in. Exaust removal system is reading 2 amps. Ignition system is reading .3 amps. Air movement system is reading 6 amps. WD40 wipedown on the system.


Clay K.

Clay K. Job Checkin

No A/C, off on high pressure switch due to metal cover on air discharge, see photo, reset safety and test ran, coumpressor run load amps factory spec 16.67, actual 7.8, outdoor fan full load amps factory spec 1.1, actual. 6, voltage enhancement system factory spec 40/5, actual 39.7/4.9, operation normal at this time. Outdoor disconnect handle is broken and should be replaced.