He was very technical savvy on problems of thermostats and heaters not communicating properly. My system has done just fine since his changes. I appreciate his talents and ability. Thank-you for taking care of the problem quickly. I appreciate your service.
She did a good job on every call I made to the office. THANK YOU
Kyle took his time and showed me the problem and how to fix it.
Paul did an excellent job. He was following up when another Moon Technician noticed that something may not be working properly with the furnace. Paul quickly assessed the situation. Paul has been out to do preventative maintenance on my system several times and when Paul is the Tech I always feel that the service is the highest quality.
He was kind, thorough and amazing with my animals following him around
Koz was on time (Actually early). He was very thorough and explained what he was doing, why he was doing it and answered my questions. Great job!!
As always a good job. This type of service gives me confidence in my heat and AC equipment. Thank You. Hank
Moon Air diagnosed the issue properly and repaired it quickly. Thank you!
Went over unit found heat droop set at 0 set heat droop too 3 if it happens again recommend replacing system control
This estimate includes: - Installing new 15A GFCI breaker for existing spare circuit in main panel - Junction existing spare circuit under the frame of stairs to allow for extension of circuit to feed receptacles in indoor pool room - Running new wires in conduit on outside wall to re-feed existing receptacles in the indoor pool room. This option would allow for an installation with no visible wires indoor - Installing new quad outdoor weatherproof box with weatherproof enclosure on side wall - Installing quad receptacles in new outdoor box
Crown Mod. TWZ100BOLT3PSU SN:CROWNB000604250 Checked operation of boiler. Burner motor is very noisy but system is working properly. WO-TNFR253781 Replaced burner motor.
Repaired return drop duct. Caped off gap from cold air boot to filter rack. Secured bottom of cold air boot to filter rack WO-TNFR251327
No heat, main burners had a little bit of rust, removed and cleaned.
Low heat from the system, found to be low on coolant due to failed indoor heat exchange system.
WO-TNFR246126 Replaced combustion pressure sensing system and repaired exhaust pipe that was leaking started up system ran system. System is functioning as intended at this time
Noise from the outdoor system, checked system, no noise at this time, no codes stored.
See previous invoice
Error code EE1 low stage pressure switch circuit is closed at start of heat cycle. Need to replace low stage pressure switch.
Cleaned all indoor air circulation systems and coils with water and chemicals. Cleaned upstairs water removal system. Coils have no leaks. Outdoor unit has no leaks. Operation normal at this time.
WO-TNFR239011 fixed refrigerant leak, recovered five pounds of R410A , repaired leak on suction line at outdoor heat pump. Checked for leaks with nitrogen at 350 psi pulled a vacuum, recharged freon 7.5 pounds of R410A test ran and checked operation heat rise is 41 degrees system is functioning as intended at this time
Reconfigured thermostat and furnace programming.