1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews
for chesapeake city, md

Rated 4.9 out of 5 stars based on 33 customer reviews

Great service

Courteous and professional technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service is always awesome


Response from Moon Air Inc.:

Thank you for the 5 stars! It’s so great to hear that your hvac service was so amazing!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

He was great and I hope it was worth the extra cost.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, Cameron is great guy!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Clay is the best👍

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Jeff did a great job and very nice guy if I have a problem again I hope you send him again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Consistently professional courteous service

Moon Air, shows up when they say will and their technicians are friendly and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service! Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service! Outstanding job! Great people! Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Graig did not come here George did. Service as always was great.

I re-enlist to your yearly service because you remind me of what needs to be done and do it on time. My home is warm and cool in the proper weather, what more can I ask for ???

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service! Great People!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service! Great People!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for chesapeake city, md

Matthew  F.

Matthew F. Job Checkin

Club ac rejuvenation, Supply has a temperature of 49 degrees. Return has a temperature of 70 degrees. Delta t of 21 degrees. Replaced air filter with a customer supplied filter. All indoor control board and electrical connections are secure. The blower wheel is clean and spins freely without restriction. The indoor voltage enhancement system is reading 9.9uf and with a factory spec of 10uf it is within the allowable fault. Cleaned out ez trap with the provided brush. Checked evaporator coil and pan both are clean and looking good. Wd40 wipe down of the indoor unit. The outdoor voltage enhancement system is reading 44.8/4.9uf and with a factory spec of 45/5uf it is within the allowable fault. The electrical gateway is without any pitting or burn marks and looks good. All outdoor control board connections are secure. Brushed off the outdoor electrical compartment. Cleaned off outdoor coil as well as the bottom of the unit to clear out all of the drain holes. System is operating normally


Mike R.

Mike R. Job Checkin

Inspected two air conditioning systems. 2nd floor high velocity system. Poor access to indoor heat transfer system. Access panel is size of emergency pan and equipment. Customer must provide access to serviceable area of equipment. Outdoor heat transfer system clean. Water removal system working. Air filters (wall return geills) clean. Voltage enhancement system. 45/7.5 actual 47.2/7.5. Refrigerant level good 25o delta t. (410a system) Inspected 1st floor system. Air filter clean. Outdoor heat transfer system clean. 18o delta t. Voltage enhancement system 40/5. Actual 40.9/5. Refrigerant levels good. (R22 system)


Mike R.

Mike R. Job Checkin

Removed and replaced voltage enhancement system


Mike R.

Mike R. Job Checkin

Checked air conditioning. Checked air movement system.operatimg properly. Air filter clean. Checked outdoor heat transfer system. Found compromised voltage enhance,ent system. Replaced. Emailed invoice. Funeral service started. Unable to speak to Mr Foard.


Keith F.

Keith F. Job Checkin

2.5 ton heat pump. Switching from oil to electric. Will decide this weekend


Mike R.

Mike R. Job Checkin

Check air conditioner. Cleaned outdoor heat transfer system. Replaced k supplied air filter. Checked indoor heat transfer system, clean. Voltage enhancement systems within factory specification. 10/ actual 10.07. 45/3. Actual 49/2.7. Air movement system clean. Flushed water removal system. Replaced customer supplied batteries in thermostat. 17o delta t


Greg H.

Greg H. Job Checkin

Changed air filter supplied by customer. Cleaned drain and tested with water. Evaporator and blower are clean electrical connections are tight voltage enhancement system read within factory spec of 80uf actual 76.2 voltage gateway looks fine compressor amps 10.1 vs factory spec of 25. Getting 19 degree delta t operation normal at this time


Clay K.

Clay K. Job Checkin

No A/C, checked system and found that the outdoor system was off on low pressure lock out, reset and test ran, suction in cooling dropped to 59 psi, in heat suction 140, indoor pressure control has failed in cooling and needs to be replaced


Clay K.

Clay K. Job Checkin

Club service A/C, changer customer supplied air filter, delta t 18 degrees, compressor run load amps factory spec 10.9, actual 3.8, outdoor fan full load amps factory spec. 95, actual. 8, voltage enhancement system factory spec 35/5, 34.5/4.9, operation normal at this time.


Blake B.

Blake B. Job Checkin

Ac club rejuvenation, delta t 15, voltage enhancement system 4.65fp 5 factory. Cleaned ez trap, checked air filter, doesn't need to be changed yet almost brand new. Checked all connections everything is secure and tight. Wd40 wipedown on unit. Outdoor unit, cleaned leaves from bottom of unit, did not need to spray coils as unit was clean and fairly new. Voltage enhancement system 37.5fp 40 factory, fan 4.69fp 5 factory. Unit running well and no issues. Wiped down unit


Clay K.

Clay K. Job Checkin

Indoor:Changed air filter, checked blower wheel, no indoor capacitor. Outdoor: capacitor factory 35, FP: 33.48, factory fan 5, FP: 4.77. Coil clean, took leaves out from Unit, wiped down Unit with wd40.


Keith F.

Keith F. Job Checkin

Customer wants multiple quotes. Will call customer Tuesday April 12 to discuss moving forward. Work to be performed in May. Return drop 14x24 Return and supply 10x24 Add filter rack with tabs


Greg H.

Greg H. Job Checkin

Cleaned all filers wiped inside and outside minspints head units. Cleaned evaporator coils checked units for error codes sprayed rusted inhibitor on rust spoy on outdoor to prevent it from geting worse operation normal at this time


Greg H.

Greg H. Job Checkin

Clean filters, evaporator coils, and wiped down inside and out head units. Lovked door and put keys back. operation normal at this time.


Paul N.

Paul N. Job Checkin

Found system low on refrigerant. Indication of leak(s) in heat transfer media.