I am extraordinarily pleased with the service provided by Jason and his team. From the initial set up of the project to final clean up, everything went beautifully. Everyone involved was courteous, neat and professional. I was thoroughly informed about every step of the entire installation and was involved to actually observe how the process was going. The new equipment was tested for proper operation before anyone left at the end of the installation. Jason has created thoughtful team that delivered on all his promises. I would gladly recommend Moon and Jason to anyone who need HVAC services.
Clay diagnosed three issues with our upstairs system and associated outdoor unit. He was able to repair one on the spot; the other two will require a return trip with materials. He was courteous and efficient and took the time to explain everything and answer questions.
Response from Moon Air Inc.:
We are incredibly grateful that you took the time out to leave us a 5-Star review.
Very thorough and good explanation of findings. Friendly demeanor.
Response from Moon Air Inc.:
Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Jack did a great job with our seasonal cleaning and inspection of our HVAC. He was conscientious and polite. Great Job!!
Response from Moon Air Inc.:
Thank you for the wonderful review and for taking the time to share your feedback.
Howard was very thorough and conscientious in his work. He was also very respectful of our clean home by putting booties on over his shoes.
Howard arrived and went right to work. He moves quietly but with purpose. He did not leave one stone unturned. He kept going until he found the solution!!!!! THANK YOU HOWARD. Such a professional!!!
Response from Moon Air Inc.:
Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.
as I am enrolled in the gold plan, service was addressed quickly. However, my 2 1/2 year old unit has a part that needs replacing. Of course this happens during an extremely hot spell!!!! so we will wait for the part to arrive. Paul was wonderful and did his very best. He is knowledgeable and was very kind
Workers were very impressive, they did excellent work.
Ac club rejuvination: delta t was 16. Air movement system was clean and clear of all debris and signs of concern but I wiped off just in case. Air filter system was dirty but they don’t have anymore air rangers so they will order more. All wiring was clean and secure. Drain line was clean and clear of all debris. Cleaned off inside and outside of indoor unit with proper cleaner and wipes. Outdoor voltage enhancement system was running at 34.9/5uf. Factory spec is a 35/5uf. Voltage gateway system was clean and clear of all signs of concern or debris. Cleaned off inside and outside of outdoor unit. System running at normal operation at this time.
Joyce wants to see Delmarva.Power bills with customers that have these many splits before she moves forward
Club AC: delta T 20 degrees. Changed filter customer supplied. Indoor voltage enhancement system rated 10uf actual is 10.1uf. Indoor Coil clean. Indoor fan was clean. Checked electrical connections. Outdoor RLA rated 17.5 amps actual is 8.1 amps. Outdoor fan amps rated .95 actual .71. outdoor voltage rated 45/5uf actual 45.2/4.9. cleaned outdoor coil. Flushed drains with cleaner.
Found lag screws pulled out of wall. Resecured wall bracket.
WO-TNFR265896 Found no power to control circuits. Found fuse blown on electronic control board. Traced short circuit to wiring in outdoor unit. Replaced damaged wiring and checked operation. System working properly at this time.
Single zone Mini split AC only, need to return
Upon arrival found oil pump starting too fail gave estimate do not recommend repair due too age of system
WO-TNFR227372 did gold package test ran operation normal at this time
This estimate includes: - Ensuring the circuit in sanctuary has appropriate ground-fault protection. - Adding (4) new circuits to sanctuary. (2) circuits will be dedicated for the music pit and (2) circuits will be dedicated for the soundstage - Replacing all 2 prong receptacles in sanctuary with new 3 prong receptacles.
Replaced wheel bearing test ran operation normal at this time