Byron S.

Byron S. Job Checkin

Upon arrival technician found that the compressor has sorted out, even with a hard start kit the compressor has the right amount of power but will not start. The compressor or condenser will need to be replaced. The replacement part should be covered under the manufacturers warranty, but the labor warranty is up so the customer will need to pay for the labor.


Byron S.

Byron S. Job Checkin

Upon arrival the technician replaced failed 45 x 5 capacitor. System working properly at this time.


Byron S.

Byron S. Job Checkin

Upon arrival technician found a failed 50 x 5 capacitor. The technician replaced a failed 50 x 5 capacitor. System working properly at this time.


Byron S.

Byron S. Job Checkin

Upon arrival the technician spoke with the customer, the customer explained that her master bedroom is not getting enough airflow and it’s getting too hot. The technician checked the temperatures and found that the whole house has a 17° difference with a 15° in the master bedroom along with the master bathroom and closet. Upon further inspection the technician found that the system is working properly but the ductwork on this System is not routed correctly, so the master bedroom bathroom and closet do not get adequate airflow due to the fact that the dust that it comes off of has around five Y’s completely cutting down the airflow to around 30%. The technician also found that the windows are single pane and the temperature on the window is around 100°F. This is causing the house to heat up when the AC shut off. The technician recommends replacement of the ductwork in order to get the proper amount of airflow to the rooms, also recommends replacement of the windows in order to ke


Byron S.

Byron S. Job Checkin

Upon arrival technician replaced the field 1/3 hp 1075 RPM blower motor. System working properly at this time.


Byron S.

Byron S. Job Checkin

Upon arrival of the technician found that the blower motor was not coming on. The technician checked and found that the system had a failed capacitor. The technician replaced the failed capacitor. The technician put the system back together and turn the system on, system is now working properly at the time. The technician believes that this unit is on its way out the door especially the furnace, the blower motor doesn’t sound too good, even though it’s not over Amping. The system is completely rusty and deteriorating, the system is from 2002 of October.


Byron S.

Byron S. Job Checkin

Upon arrival technician found that the 45 x 5 capacitor had failed. The technician replace the 45 x 5 capacitor. System working properly at this time.


Byron S.

Byron S. Job Checkin

Upon arrival the technician inspected the AC unit. The technician began in the attic, the technician checked the evaporator coil and found a leak on the suction line and a leak on the TXV Both inside the coil. The technician checked the refrigerant levels and found that the system is low on 410 a refrigerant. The evaporator coil will need to be replaced.


Byron S.

Byron S. Job Checkin

Upon arrival technician found that the system is clogged with dirt, which is causing the system to be too hot and cannot cool the house properly. The system needs to be cleaned. Currently the system is working properly but as the day gets hotter it will continue to get worse.


Byron S.

Byron S. Job Checkin

Upon arrival technician found failed 50 x 55 capacitor. Technician replaced the failed 50 x 5 capacitor. System working properly at this time.


Byron S.

Byron S. Job Checkin

Upon arrival the technician performed a preseason AC inspection. The technician started in the attic with replacement of the filter. And inspected the furnace, the drain lines, and the coil. The technician Then moved onto the outside unit, checked the electrical and the refrigerant, system working properly at this time. During the preseason AC inspection the technician inspected the hot water heater. The technician found that one of the flex lines of the water heater is currently leaking over the water heater. And causing rust buildup on top of the water heater. The technician spoke with the customer, and the customer notified the technician that the hot water heater has been draining out of the bottom of the house for the past three months. The technician called the office and is having joe come out to give them options on replacement. Filter size 20 x 25 x 4


Byron S.

Byron S. Job Checkin

Upon arrival technician found a failed 55 x 5 capacitor. The technician replaced the failed 55 x 5 capacitor. System working properly at this time.


Byron S.

Byron S. Job Checkin

Upon arrival technician found that the 50 mfd capacitor had failed. The technician spoke with the customer and explain that this happens due to his compressor pulling high amps. The technician made a recommendation to install a hard start kit to prevent this from happening again. The customer accepted the recommendation and move forward with installation of a hard start kit and replacement of the capacitor. System working properly at this time.The technician spoke with the customer and explain that this happens due to his compressor pulling high amps. The technician made a recommendation to install a hard start kit to prevent this from happening again. The customer accepted the recommendation and move forward with installation of a hard start kit and replacement of the capacitor. System working properly at this time


Charles L.

Charles L. Job Checkin

Upon arrival I found a failed capacitor for the blower motor in the attic. After replacing capacitor the system is working properly


Charles L.

Charles L. Job Checkin

Upon arrival the technician found that the system is operating properly at this time. It is currently 88° outside the homeowner has a thermostat set to 66° and the current temperature inside the home is 66°. The homeowners concern is that during the afternoon hours when the heat is that it’s hottest the indoor temperature rises to 74°. After investigating the technician was able to determine that the system is unable to keep up with the extremely high temperatures due to age and extremely poor condition. There are numerous air leaks inside of the attic and the ductwork is extremely old and shredded which is allowing the air to heat up before it makes its way into the home. Due to the damage DuctworkThe system is also mixing in hot air into the air conditioning system. Proactive replacement of the entire HVAC system as well as the ductwork is recommended at this time due to age and condition however the system is functioning properly at this time.