Job Checkin

Filter replaced with customer supplied Supply 56 Return 83.5 Condensation line clear Blower wheel ok condition Fan capacitor 6.9 rated for 7.5 Fan motor.67 Outdoor coil needs cleaning Outdoor temp 84 129 saturated temp 44 line temp 50 312 saturated temp 98 line temp 90 Subcool 8 Super heat 6 Contactor operational Capacitor 38.3/5.01 rated for a 40/5 Compressor 5.0 Outdoor fan.68 No broken or damage wiring