MY PLUMBER HEATING COOLING & ELECTRICAL
MANASSAS, VA 20109
800-280-2820

Job Locations
for bristow, va


Map of Bristow VA
CRAIG M.

CRAIG M.


Job Checkin

Outdoor temp 65 Attic Supply 46 Return 67 Condensation line good Filter homeowner will replace Blower wheel good condition Blower motor capacitor 9.9 rated for 10 Blower motor .7 Outdoor coil Compressor 6.4 Fan 1.1 Contactor operational Capacitor 38/1.7 Running pressures 410a 238 saturated temp 81.6 line temp 77 112 saturated temp 37 line temp 50.4 Superheat 13.4 Subcool 4.6 Basement Supply 48 Return 67 Condensation line good Filter replaced with customer supplied Blower motor capacitor 10 Blower.6 Outdoor coil needs cleaning Compressor 5.3 Fan. 3 Contactor operational Capacitor 42/4 Running pressures 410a 108 saturated temp 35.5 line temp 40.5 255 saturated temp 84 line temp 73 Subcool 11 Superheat 5 No lose or damage wiring After homeowner approval cleaned an replace both capacitor System are now in good physical and operational condition Thank you for your business