MY PLUMBER HEATING COOLING & ELECTRICAL
MANASSAS, VA 20109
800-280-2820

Local Reviews
for broadlands, va

Rated 4.9 out of 5 stars based on 7 customer reviews

Install s humidifier

Great work


Response from MY PLUMBER HEATING COOLING & ELECTRICAL:

Here at My Plumber Heating and Cooling, customer feedback like this is simply priceless, thank you for the continued loyalty and support!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service as always!!!

Have used them on several occasions and every technician has been excellent!!


Response from MY PLUMBER HEATING COOLING & ELECTRICAL:

Thank you for the 5 Star Review! We will be sure to share your feedback with the technician who serviced you as well as our Management Team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always outstanding service!

Chris was exceptional! His response time was IMMEDIATE. He was extremely polite and well informed. He did not waste anytime and got right to the problem. He provided additional information to keep everything running smoothly and was very conscientious to insure that everything was completed within budget and timely manner. We have used My Plumber throughout the 21 years we have been in this home and they ALWAYS provide outstanding service!


Response from MY PLUMBER HEATING COOLING & ELECTRICAL:

• Thank you for the great feedback. We will be sure to relay these comments back to the technician and his manager. As always thank you for your continued loyalty and support. We hope that in the future if you or anyone you know needs plumbing or HVAC service, you will send them our way. We will make sure they to receive the excellent quality of service you received on our most recent visit. Kind regards, The My Plumber Heating and Cooling Team

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from MY PLUMBER HEATING COOLING & ELECTRICAL:

Thank you for the great feedback. We will be sure to relay these comments back to the technician and his manager. As always thank you for your continued loyalty and support. We hope that in the future if you or anyone you know needs plumbing or HVAC service, you will send them our way. We will make sure they to receive the excellent quality of service you received on our most recent visit. Kind regards, The My Plumber Heating and Cooling Team

  • Overall Experience
  • Quality
  • Price
  • Convenience

Toilet Replacement

Nathan was excellent. Replacement was quick and easy with toilet I purchased. Would work with them again.


Response from MY PLUMBER HEATING COOLING & ELECTRICAL:

Thank you for the great feedback. We will be sure to relay these comments back to the technician and his manager. As always thank you for your continued loyalty and support. We hope that in the future if you or anyone you know needs plumbing or HVAC service, you will send them our way. We will make sure they to receive the excellent quality of service you received on our most recent visit. Kind regards, The My Plumber Heating and Cooling Team

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very responsive.

Dave was very responsive and thorough. He had great advice and was more than willing to explain all aspects of what he was working on. He came out and worked non-stop for 6 straights hours to repair and replace nearly all major aspects of the house's plumbing system. I would highly recommend him and My Plumber Heating and Cooling for all household plumbing needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Monday

Professional value received for fair price.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for broadlands, va

CRAIG M.

CRAIG M. Job Checkin

Homeowner would like me only for HVAC Attic unit Supply 56 Return 72 Filter Condensation good Blower wheel good condition Blower motor capacitor 7.4 Blower motor.8 Outdoor coil needs cleaning Compressor 4.6 Fan .3 Contactor operational Capacitor 37.6/4 Running pressures 410a 117.6 saturated temp 39.7 line temp 57.3 297 saturated temp 95 line temp 77 Subcool 17 Superheat 17.4 Basement Supply 56 Return 72 Filter good Condensation line good Blower wheel good condition Blower capacitor 12.5 Blower motor.9 Outdoor coil needs cleaning Compressor 6.3 Fan .8 Contactor operational Capacitor 40.2/4.9; Running pressures 410a 122.3 saturated temp 41.7 line temp 51.3 272 saturated temp 91 line temp 80.5 Subcool 10.5 Superheat 9.4 No lose or damage wiring Cleaned both unit after homeowner approval Home declined replacement of capacitor Thank you for your business


CHRIS  W.

CHRIS W. Job Checkin

Install customer supplied kitchen faucet


GENTI P.

GENTI P. Job Checkin

Psi 60 chl - Repair main floor w/c minor rebuild


ADAM O.

ADAM O. Job Checkin

Repaired 1/2” soft copper gas line underneath kitchen range. Installed customer supplied garbage disposal


TED W.

TED W. Job Checkin

Psi54-Found basement w/c leaking from tank bolts due to 10 yrs old tank failure.did a major tank rebuild to that one but also found 2nd w/c in basement with failure in tank as well.did a minor tank rebuild to that one and another major tank rebuild to main floor p/r w/c.installed a new flapper to guest bath w/c on main floor as a courtesy n/c.10 yrs old home with same hvac and w/h system.customer wasn’t interested in hsp at this time.2 yrs warranty on major tank rebuild a 1 yr on minor rebuild.


DAVID B.

DAVID B. Job Checkin

Minor rebuild of wc tank in powder room....1 year warranty


ADAM O.

ADAM O. Job Checkin

Snaked upstairs jack and Jill bathroom. Pulled back hair ball and band aid. No warranty


GENTI P.

GENTI P. Job Checkin

Psi 60 chl - Replace cartridge delta in the m/b shower in the 2 floor


CORY R.

CORY R. Job Checkin

I inspected furnace system to include: R-410a TXV -All electrical wiring, motors, and components -All safeties ok -drain is clear -evap coils are clean -condenser coils are clean Iddb 65 Oddb 13 Top floor system had a dirty blower and a burned wire on line wires. I rewired furnace and pulled and cleaned blower wheel. I also replaced the humidifier pad on the downstairs unit. Both systems are in good working order.


ADAM O.

ADAM O. Job Checkin

Installed 3 new customer supplied toilets with no warranty, as parts are customer supplied. Installed 3 new shutoff valves for the toilets with one year parts and labor warranty. Spoke with customer about the replacement of the other fixture shutoff valves in the home.


CORY R.

CORY R. Job Checkin

Replaced induced draft motor. Replace 10’ section of flue pipe to correct water leak. System is in good working order.


HOOMAN K.

HOOMAN K. Job Checkin

Install customer provided humidifier with tech Corey Rudder. Test it out. All working properly at this time.


MOE A.

MOE A. Job Checkin

minor r3build in basment bath


DAVID B.

DAVID B. Job Checkin

Replaced sump pump with check valve...2 years warranty,replaced wc Toto Drake White in master bathroom...2 years warranty,replaced flapper and dye tested in powder room......estimate....hallway bathroom...to add insulation in walls and lay new boards around tub...customer supply tiles...3653$.......to remove tub ,add insulation in walls and floor if needed , lay boards and shower liner....customer supply tiles....7476$


BARRY B.

BARRY B. Job Checkin

Performed semi annual maintenance check on Goodman unit,check air filter,check blower motor,wheel,and assembly,check evaporator coil,flush drainage system,inspect heat exchanger,check all electrical connections and tighten all loose connections,check electrical absorption system,check outdoor a/c unit,check condenser coil,check compressor,check fan motor,check electrical delivery system,check and replaced failing electrical absorption dual system 45/5mfd,check temp split 20F delta,check refrigerant pressure,check all cooling,system is cooling and operating Number of Systems: Equipment Age: Model and Serial #'s in SMAC: Y/N Freon: R22 or R410a Metering Device: Fixed or TXV Required subcooling: _____F Supply Air D/B: _____F Supply Air W/B: _____F Return Air D/B: _____F Return Air W/B: _____F Indoor Delta T Target Range: Capacity Check: ____F W/B Delta T:_____ Suction Pressure PSIG: Suction Line Temp: Saturated Suction Temp: Suction Super