Very professional knew his job well. Great service!!
Performed routine maintenance on air-conditioning system. Also opened up condenser fins a little bit more and clean the coil. head pressure went down significantly. Discharge air temperature is 57° with a space temperature of 73.
Performed maintenance on Navien boiler in Dracut. Cleaned flame sensor and igniter. Checked operation of condensate pump. Cleaned condensate pump basin. Cycled system from thermostats and domestic hot water.
Checked system operation. Customer noted problem with cooling temperature on warmer days. System would take a lot longer than anticipated to cool home. Reviewed Ecobee settings. Found it not setup for 2 stage operation. So cooling capacity was limited to first stage. Made corrections to compressor staging. Now system running properly. Checked refrigerant pressures. System running great!