Furnace maintenance. Cleaned and serviced furnace. Tested flame sensor, pressure switches, ignition, gas valve voltage, blower motor amperage and capacitor. Inspected heat exchanger. Cleaned flame sensor and replaced furnace filter that customer provided. Replace humidifier pad. Tested sump pump battery, battery tested good. Everything is operating in adequate working condition at this time Renew annual VIP service plan today.