Brennon was professional and did a great job!
Response from PDM Plumbing, Heating, Cooling Since 1885:
Yes Ann, Brennon is a great guy to have on your team. Thanks for sharing your AC maintenance review and for your trust in PDM. We're hear when needed.
Response from PDM Plumbing, Heating, Cooling Since 1885:
Hello David, thanks for your bathroom plumbing repair review. Happy that Anthony took good care on you. Thanks again for calling PDM for any plumbing, heating and cooling maintenance.
I had a split copper pipe that was not easy to get to and PDM showed up and had it repaired within an hour. Very personable and caring.
Response from PDM Plumbing, Heating, Cooling Since 1885:
Wonderful review Zach. John is smiling. Thanks for taking the time to share your frozen pipe service and glad John got you back to normal quickly. Thanks again for choosing PDM and we'll be here when you need service. Happy new year!
Response from PDM Plumbing, Heating, Cooling Since 1885:
Good to hear Pete got your hot water flowing again. Thanks Krista for your service review and for choosing PDM for your new water heater installation. Next time you are ready to maintain your home comfort systems please call your team at PDM Plumbing, Heating, Cooling Since 1885. Thanks Krista!
Very professional
Response from PDM Plumbing, Heating, Cooling Since 1885:
Happy to hear Chris' furnace repair impressed you and got you back to normal. Thanks Gary for taking the time to share a review and for choosing PDM Plumbing, Heating, Cooling Since 1885. We look forward to maintaining your equipment for safe, efficient operation...
AC maintenance. Cleaned and serviced condensing units. Tested capacitors,contactors,fan motor amperage and compressor motor amperages. Check all 410 refrigerant levels. In unit #3 in alley, replaced a run capacitor due to being low and not turning on unit. Unit #2 was low on refrigerant, added 1-1/2lbs of 410 to achieve adequate efficiency. Replaced all furnace filters. Order a box of 20x25x1 filters from Rogers for this job. All units are cooling as they should at this time.
Commercial HVAC service. Inspected 2 roof top units, return air is blanked off. Outside air is not plugged in on unit. Inspected exhaust fan, flex cut is not connected to anything. Will work up estimate on cutting in return grills. New zone system and exhaust fan installed.
Bathroom plumbing repair. Repaired leak in cpvc piping for shower.
Look at tankless heater. Found water heater is not vented and no drain on unit. Recommend replacing tankless heater with vent and drain installed. Or replace with standard 40 gallon water heater and rework gas water and flue vent wye. Customer to call Westinghouse to see if he can get it under warranty if they do that I told him we would quote install. No warranty on this heater from us.
Cleaned and diagnosed furnace. Tested flame sensor, pressure switches, hsi, fan motor amperage and capacitor, and inducer motor amperage. Cleaned out drain lines. Replaced flame sensor and hsi due to corrosion. One visit will be used on plan and customer will have one visit remaining in spring.
Bathroom plumbing repair. Replace lavatory faucet and drain, replace tub pop up and over flow plate.
Water heater repair. Pulled gas burner to locate and clean 3 flame sensors. Hot water is flowing now.
Cleaned and serviced all 7 condensing units. Tested all capacitors, contactors, and fan motor amperages. Also checked all refrigerant levels. The conclusions of units as followed. Unit #1 alley- added 1lbs of R410a refrigerant. Capacitor,contactor, and fan Motor were in accurate working condition. Unit #2 alley- added 1-1/2 lbs of R410a refrigerant. Capacitor,contactor,and fan motor were in accurate working condition. Unit #3alley- replaced a single run capacitor 12.5mrf. Contactor and fan motor Amperage were in accurate working condition. The refrigerant levels were accurate. Unit #1 rooftop- added 2lbs of R410a refrigerant. Capacitor,contactor and fan motor amperage were all in accurate working condition. Unit #2 rooftop- Added 1lbs of R410a refrigerant. Capacitor,contactor,and fan motor ampera
Air chamber for laundry box froze and split, cut out piping and repaired air chamber with coupling. Then put piping back in.
Furnace humidifier repair. Angle stop for humidifier was leaking. Replace shut off valve.
ESTIMATE FOR NEW COMMERCIAL HVAC UNIT.
Furnace repair. Replaced exhaust piping of furnace.