467 Ruby St
Joliet, IL 60435
815-726-6264

Local Reviews
for naperville, il

Rated 5.0 out of 5 stars based on 2 customer reviews

Courteous, sociable, experienced, knowledgeable

Chris was great. I would be happy for his return anytime with my furnace or air conditioner. I was very happy to know that the furnace issue was a minor issue and not something big considering my furnace is just over 2 years old.


Response from PDM Plumbing, Heating, Cooling Since 1885:

Wonderful news Sandra! So glad Chris gave you peace of mind for your furnace repair. Thanks for your trust in PDM Plumbing, Heating, Cooling Since 1885. We look forward to our next maintenance visit to keep you safe and comfortable. Until then, stay safe.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous, sociable, experienced, knowledgeable

Anthony has always given me his best honest advice and his best service. He is courteous, sociable, experienced, and knowledgeable.


Response from PDM Plumbing, Heating, Cooling Since 1885:

You hit the nail on the head with that observation Sandra. Anthony is a great guy to have on your team. Thanks for sharing and for you continued trust with PDM Plumbing, Heating, Cooling Since 1885!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for naperville, il

Dan K.

Dan K. Job Checkin

2- electric boilers diagnostic done today 1-North boiler 1 of 3 fuses are blown on main feed going to this boiler, this fuse will have to be changed by a electrician before any other diagnostic can be done on this boiler. 2- south boiler Power is good to this boiler but the low voltage fuse is blown on this boiler this is the control side of the boiler, tried to locate fuse I was unsuccessful on this, I called Dave at the shop he could not locate one at this time we need to order and return for further inspection. Office needs send bill Office had me return today. 12/14/2023 North boiler check no heat 1- boiler has power all three legs pump control is not calling for heat. 2- found floor control turned all the way down this is not a thermostat it control’s temperature of the slab set at 65* boiler is on and heating. South boiler 1- found bad fuse on 24 volt side this fuse was never changed from last time. I replace fuse boiler came on stage one , when the time delay pulled in st


Brennon E.

Brennon E. Job Checkin

Cleaned and serviced furnace. Tested flame sensor, pressure switches, hsi, fan motor amperage and capacitor, and inducer motor amperage. Cleaned out exhaust pipe and drains. Washed out furnace filter and reinstalled under blower. Everything is in adequate working condition. Customer has one more visit remaining on plan for condenser in 2024 season.


Brennon E.

Brennon E. Job Checkin

Cleaned and serviced furnace. Tested flame sensor, pressure switches, hsi, fan motor amperage and capacitor, and inducer motor amperage. Cleaned out blower motor cabinet. Blew out drain lines. Everything was in adequate working condition. Changed furnace filter that customer provided. Customer has one more visit on plan for spring.


Brennon E.

Brennon E. Job Checkin

Cleaned and serviced condensing unit. Tested capacitor, contactor, and fan motor amperage and everything was in accurate working condition. Tested r410a refrigerant levels, and those too were in accurate range. Everything is working greatly. Customer wants to renew maintenance program.


Anthony F.

Anthony F. Job Checkin

Leak search with nitro to 450 psi, used bubbles found no leaks held for 30 minutes, pulled vac down to 500 micron added 4.3 #r410a, replaced capacitor 40+5


Anthony F.

Anthony F. Job Checkin

AC maintenance. Unit low on refrigerant, customer want to replace air conditioning unit.


Anthony F.

Anthony F. Job Checkin

Water leak in the Brown house and clogging the sink lines. Found the water softener to be in bypass mode, programmed timer and hardness into sofetner and put back into service. Ran through regeneration and also performed hardness test on well - 35 grains of hardness. If problems with water persist I recommend chlorinating the well and replacing the water softener


Pete W.

Pete W. Job Checkin

Water heater leaking, needs to be replaced. Replaced water heater


Chris G.

Chris G. Job Checkin

Heating repair. Low heat call out. Customer stated that thermostat said that it had been running for two hours. Upon detailed inspection found the pressure switch to be intermittent. Vacuum started at -1.30 then reduced to -1.00. Pressure switch at -.60. Replaced pressure switch and hose.


Chris G.

Chris G. Job Checkin

Clean and check furnace system. Renewed customer service agreement. This is the first visit on this new plan. 20 cent part from truck inventory


Anthony F.

Anthony F. Job Checkin

Clean, test and reset furnace to factory specs for safe, efficient operation.


Chris G.

Chris G. Job Checkin

Clean and check air conditioning system. This is the second visit on this annual HVAC service plan.


Anthony F.

Anthony F. Job Checkin

Central air conditioning maintenance. Clean, check ac operation. Reset to factory specs for safe, efficient operation.


Chris G.

Chris G. Job Checkin

Heating furnace repair. No heat call. Customer said air filter was very dirty because of remodeling. Heating system shut down because of high limit. Cleaned and tested furnace and replaced faulty run capacitor. Reset heating system and tested three times.


Chris G.

Chris G. Job Checkin

Heating repair. Found furnace did not have power. Upon inspection found door switch to be intermittent. Shimmed door switch, added note to interior of furnace. Need to replace door switch on next service call. No charge per technician.