5865 Old Leeds Rd
Birmingham, AL 35210
205-957-2022

Local Reviews
for helena, al

Rated 4.7 out of 5 stars based on 23 customer reviews

Great service ! Tech was awesome !

Very good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Heating a System Check up

The technician was professional and curious, performed his tasks expeditiously.

  • Overall Experience
  • Quality
  • Price
  • Convenience

The service was real good & the pricing is not to bad

Good conduct from the tech. On time with a good attitude.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

The work was done to satisfaction

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and very polite!

I was very happy with him.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

The Perfect Service Heating and Air Team did a great job. They were very responsive, explained all the process, and setup appointments that were convenient for me and my family.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Summer air service

Perfect Service did a wonderful job. The technician explained everything and was very courteous. I have been using them for the past 3 years.

  • Overall Experience
  • Quality
  • Price
  • Convenience

spring review

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for helena, al

Team Perfect Service !.

Team Perfect Service !. Job Checkin

CLEAN AND CHECK A/C UNIT. CLEAN AND CHECK CONDENSER COIL, CHECK VOLTAGE AND AMPERAGE ON MOTORS. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS, CHECK THERMOSTAT, AIR FILTER, AIRFLOW, DRAINAGE, FREON LEVELS, COMPRESSOR DELAY SAFETY CONTROLS, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS, DNS SA

CLEAN AND CHECK A/C UNIT. CLEAN AND CHECK CONDENSER COIL, CHECK VOLTAGE AND AMPERAGE ON MOTORS. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS, CHECK THERMOSTAT, AIR FILTER, AIRFLOW, DRAINAGE, FREON LEVELS, COMPRESSOR DELAY SAFETY CONTROLS, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS, DNS SA

Brannon P.

Brannon P. Job Checkin

CAME OUT ON A QUOTE ON EQUIPMENT. INSTALLED 4TON FURNACE 12YR. INSTALLED UV ERSA. MADE SURE EQUIPMENT WAS INSTALLED PROPERLY AND WORK AREA WAS CLEAN WHEN FINISH. CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, HUMIDIFIER, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS.

CAME OUT ON A QUOTE ON EQUIPMENT. INSTALLED 4TON FURNACE 12YR.
INSTALLED UV ERSA.
MADE SURE EQUIPMENT WAS INSTALLED PROPERLY AND WORK AREA WAS CLEAN WHEN FINISH. 
CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, HUMIDIFIER, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS.

Andrew S.

Andrew S. Job Checkin

2ND TUNE-UP UNDER SERVICE AGREEMENT FOR 3YR HEATING UNIT. THERE ARE 2 UNITS. RENEWED SERVICE AGREEMENT ON BOTH UNITS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK HEAT EXCHANGER AND HIGH LIMIT CONTROL. CHECK MANIFOLD GAS PRESSURE AD FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, AIRFLOW, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS.

2ND TUNE-UP  UNDER SERVICE AGREEMENT FOR 3YR HEATING UNIT. THERE ARE 2 UNITS. RENEWED SERVICE AGREEMENT ON BOTH UNITS. 
CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK HEAT EXCHANGER AND HIGH LIMIT CONTROL. CHECK MANIFOLD GAS PRESSURE AD FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, AIRFLOW, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS.

Jacob R.

Jacob R. Job Checkin

1ST MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 12YR HEATING UNIT. REWIRED PURIFIER, OUTDOOR FAN, PULLING MA APS BUT RUNNING WELL. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HUMIDIFIER, AND ALL ELECTRICAL CONNECTIONS.

1ST MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 12YR HEATING UNIT. REWIRED PURIFIER, OUTDOOR FAN, PULLING MA APS BUT RUNNING WELL. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HUMIDIFIER, AND ALL ELECTRICAL CONNECTIONS.

Scott H.

Scott H. Job Checkin

1ST CLEAN AND CHECK UNDER SERVICE AGREEMENT FOR 2YR HEATING UNIT. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HEAT EXCHANGER HIGH LIMIT CONTROL. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK HUMIDIFIER AND ALL ELECTRICAL CONNECTIONS.

1ST CLEAN AND CHECK UNDER SERVICE AGREEMENT FOR 2YR HEATING UNIT. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HEAT EXCHANGER HIGH LIMIT CONTROL. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK HUMIDIFIER AND ALL ELECTRICAL CONNECTIONS.

Scott H.

Scott H. Job Checkin

13 POINT MAINTENANCE TUNE-UP FOR A 3YR & 2YR HEATING UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, HUMIDIFIER, FAN CONTROL, ENERGY CONSUMPTION, HEAT EXCHANGER, HIGH LIMIT CONTROL, AND ALL ELECTRICAL CONNECTIONS. CHECK MANIFOLD GAS PRESSURE AND PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS.

13 POINT MAINTENANCE TUNE-UP FOR A 3YR & 2YR HEATING UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, HUMIDIFIER, FAN CONTROL, ENERGY CONSUMPTION, HEAT EXCHANGER, HIGH LIMIT CONTROL, AND ALL ELECTRICAL CONNECTIONS. CHECK MANIFOLD GAS PRESSURE AND PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS.

Andrew S.

Andrew S. Job Checkin

1ST CLEAN AND CHECK UNDER SERVICE AGREEMENT FOR HEATING UNIT. CUSTOMER HAVE 2 UNITS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS, AND CHECK ALL ELECTRICAL CONNECTIONS. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, HEAT EXCHANGER, HIGH LIMIT CONTROL, ENERGY CONSUMPTION, AIRFLOW, FAN CONTROL, AND MANIFOLD GAS PRESSURE AND FOR PROPER VENTING.

1ST CLEAN AND CHECK UNDER SERVICE AGREEMENT FOR HEATING UNIT. CUSTOMER HAVE 2 UNITS.
CLEAN AND CHECK BURNERS AND BURNER OPERATION.
ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS, AND CHECK ALL ELECTRICAL CONNECTIONS. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, HEAT EXCHANGER, HIGH LIMIT CONTROL, ENERGY CONSUMPTION, AIRFLOW, FAN CONTROL, AND MANIFOLD GAS PRESSURE AND FOR PROPER VENTING.

David D.

David D. Job Checkin

13 POINT TUNE-UP FOR 7YR HEATING UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HUMIDIFIER, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS.

13 POINT TUNE-UP FOR 7YR HEATING UNIT.
CLEAN AND CHECK BURNERS AND BURNER OPERATION.
CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HUMIDIFIER, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS.

Scott H.

Scott H. Job Checkin

SECOND CLEAN AND CHECK HEATING UNIT THAT IS 12YR, UNDER SERVICE AGREEMENT. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, HUMIDIFIER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION.

SECOND CLEAN AND CHECK HEATING UNIT THAT IS 12YR, UNDER SERVICE AGREEMENT.
CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, HUMIDIFIER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION.

Jake W.

Jake W. Job Checkin

CLEAN AND CHECK HEATING UNIT ON A 9 YR UNIT. CHECK THERMOSTAT, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, AIRFLOW, HUMIDIFIER, ENERGY CONSUMPTION, GAS PRESSURE, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS

CLEAN AND CHECK HEATING UNIT ON A 9 YR UNIT. 
CHECK THERMOSTAT, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, AIRFLOW, HUMIDIFIER, ENERGY CONSUMPTION, GAS PRESSURE, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS

Andrew S.

Andrew S. Job Checkin

CLEAN AND CHECK 17-YEAR-OLD HEATING UNIT. CHECK THERMOSTAT, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, HUMIDIFIER, GAS PRESSURE, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS.

CLEAN AND CHECK 17-YEAR-OLD HEATING UNIT. CHECK THERMOSTAT, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, HUMIDIFIER, GAS PRESSURE, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS.

Buddy B.

Buddy B. Job Checkin

CAME OUT FOR THE 2ND SERVICE CLEANING AND CHECK FOR HEATING UNIT. CHECK THERMOSTAT, AIR FILTER, GAS PRESSURE, PROPER ENERGY CONSUMPTION, FAN CONTROL, HUMIDIFIER, ALL ELECTRICAL CONNECTIONS, AND AIRFLOW. CLEAN AND CHECK BURNERS AND BURNER OPERATION. RENEWED SA.

CAME OUT FOR THE 2ND SERVICE CLEANING AND CHECK FOR HEATING UNIT. CHECK THERMOSTAT, AIR FILTER, GAS PRESSURE, PROPER ENERGY CONSUMPTION, FAN CONTROL, HUMIDIFIER, ALL ELECTRICAL CONNECTIONS, AND AIRFLOW. CLEAN AND CHECK BURNERS AND BURNER OPERATION. RENEWED SA.

Brenden H.

Brenden H. Job Checkin

SERVICE AGREEMENT CHECK-UP FOR HEATING UNIT. CHECK EVERYTHING TO MAKE SURE HEATING UNIT IS OPERATING PROPERLY. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, ELECTRICAL CONNECTIONS, GAS PRESSURE, HEAT EXCHANGER, AND ADJUST BLOWER COMPONENTS. LUBRICATE ALL NECESSARY MOVING PARTS. AND CLEAN BURNERS.

SERVICE AGREEMENT CHECK-UP FOR HEATING UNIT. CHECK EVERYTHING TO MAKE SURE HEATING UNIT IS OPERATING PROPERLY. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, ELECTRICAL CONNECTIONS, GAS PRESSURE, HEAT EXCHANGER, AND ADJUST BLOWER COMPONENTS. LUBRICATE ALL NECESSARY MOVING PARTS. AND CLEAN BURNERS.

David D.

David D. Job Checkin

CLEAN AND CHECK HT. CHECK THERMOSTAT, CHECK HUMIDIFIER, CHECK ALL ELECTRICAL CONNECTIONS, CHECK AIR FILTER, CHECK GAS PRESSURE AND FOR PROPER VENTING, CHECK HIGH LIMIT CONTROL, CHECK HEAT EXCHANGER, CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENT. LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT.

CLEAN AND CHECK HT. CHECK THERMOSTAT, CHECK HUMIDIFIER, CHECK ALL ELECTRICAL CONNECTIONS, CHECK AIR FILTER, CHECK GAS PRESSURE AND FOR PROPER VENTING, CHECK HIGH LIMIT CONTROL, CHECK HEAT EXCHANGER, CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENT. LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT.

Jesse C.

Jesse C. Job Checkin

CLEAN AND CHECK A/C. CHECK THERMOSTAT, CHECK ALL ELECTRICAL CONNECTIONS, CHECK DRAINAGE, CHECK AIR FILTER, CHECK FREON LEVELS, CHECK CONDENSER COIL. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. INSTALLED ADC. EVERYTHING IS RUNNING GREAT.

CLEAN AND CHECK A/C. CHECK THERMOSTAT, CHECK ALL ELECTRICAL CONNECTIONS, CHECK DRAINAGE, CHECK AIR FILTER, CHECK FREON LEVELS, CHECK CONDENSER COIL. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. INSTALLED ADC. EVERYTHING IS RUNNING GREAT.