Brannon P.

Brannon P. Job Checkin

CLEAN AND CHECK HT. CHECK HUMIDIFIER ELECTRICAL CONNECTION, GAS PRESSURE, BURNERS, HEAT EXCHANGER, THERMOSTAT, AIR FILTER, FAN CONTROL, AIR FLOW. RENEWED SERVICE AGREEMENT.

CLEAN AND CHECK HT. CHECK HUMIDIFIER ELECTRICAL CONNECTION, GAS PRESSURE, BURNERS, HEAT EXCHANGER, THERMOSTAT, AIR FILTER, FAN CONTROL, AIR FLOW. RENEWED SERVICE AGREEMENT.

Brannon P.

Brannon P. Job Checkin

CLEAN AND CHECK HT. CHECK THERMOSTAT, CHECK HEAT EXCHANGER, CHECK HIGH LIMIT CONTROL, CHECK AIR FILTER, CHECK GAS PRESSURE AND FOR PROPER VENTING, CHECK HUMIDIFIER, CHECK ALL ELECRICTRAL CONNECTION. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT. RENEWED SERVICE AGREEMENT.

CLEAN AND CHECK HT. CHECK THERMOSTAT, CHECK HEAT EXCHANGER, CHECK HIGH LIMIT CONTROL, CHECK AIR FILTER, CHECK GAS PRESSURE AND FOR PROPER VENTING, CHECK HUMIDIFIER, CHECK ALL ELECRICTRAL CONNECTION. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT. RENEWED SERVICE AGREEMENT.

Brannon P.

Brannon P. Job Checkin

CLEAN AND CHECK HT. CHECK THERMOSTAT, CHECK HEAT EXCHANGER, CHECK BURNES AND BURNER OPERATION, CHECK HUMIDIFIER, CHECK HIGH LIMIT CONTROL, CHECK ALL ELECTRICAL CONNECTION, CHECK GAS PRESSURE AND FOR PROPER VENTING. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT.

CLEAN AND CHECK HT. CHECK THERMOSTAT, CHECK HEAT EXCHANGER, CHECK BURNES AND BURNER OPERATION, CHECK HUMIDIFIER, CHECK HIGH LIMIT CONTROL, CHECK ALL ELECTRICAL CONNECTION, CHECK GAS PRESSURE AND FOR PROPER VENTING. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT.

Jake W.

Jake W. Job Checkin

CLEAN AND CHECK A/C. CHECK THERMOSTAT, CHECK DRAINAGE, CONDENSER COIL, CHECK AIR FILTER, CHECK FREON LEVELS, CHECK ALL ELECTRICAL CONNECTIONS, ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GREAT.

CLEAN AND CHECK A/C. CHECK THERMOSTAT, CHECK DRAINAGE, CONDENSER COIL, CHECK AIR FILTER, CHECK FREON LEVELS, CHECK ALL ELECTRICAL CONNECTIONS, ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING  IS RUNNING GREAT.

Jeffery M.

Jeffery M. Job Checkin

Checked gas lines for leaks, Checked to the condenser coil.

Checked gas lines for leaks, Checked to the condenser coil.

Technician .

Technician . Job Checkin

Service work performed for the Heil 2008 air conditioning unit with Zep con-coil cleaner. No repairs needed.

Service work performed for the Heil 2008 air conditioning unit with Zep con-coil cleaner. No repairs needed.

Brian M.

Brian M. Job Checkin

Service work performed for the Heil 2013 heat furnace. cleaned burners and burner operators, No repairs needed.


Taylor C.

Taylor C. Job Checkin

checked gas lines for leaks, cleaned gas burners, lubricated moving parts.

checked gas lines for leaks, cleaned gas burners, lubricated moving parts.

David M.

David M. Job Checkin

Cleaned and sanitized the Heil 2010 air condensing unit with Zep con-coil cleaner, no repairs needed. Checked ducts for build up, cleaned burners and checked gas lines for leaks.

Cleaned and sanitized the Heil 2010 air condensing unit with Zep con-coil cleaner, no repairs needed. Checked ducts for build up, cleaned burners and checked gas lines for leaks.

Technician .

Technician . Job Checkin

Cleaned and sanitized the Heil air conditioning unit with Zep con-coil cleaner, no repairs needed.

Cleaned and sanitized the Heil air conditioning unit with Zep con-coil cleaner, no repairs needed.

Brian M.

Brian M. Job Checkin

Repaired blower capacitor and flex fuse on 2015 Heil package unit.


Technician .

Technician . Job Checkin

Replaced stat wire for 12 Rheem package unit, the unit still covered under warranty.

Replaced stat wire for 12 Rheem package unit, the unit still covered under warranty.

Brian M.

Brian M. Job Checkin

Clean and service done on 3.5 ton heat pump and air handler. cleaned air filters, checked air flow

Clean and service done on 3.5 ton heat pump and air handler. cleaned air filters, checked air flow

Technician .

Technician . Job Checkin

Heating service on an 11-year-old Rheem. Check heat strips inside the air handler to make sure they are working properly and producing heat as needed. Check the condensate drain making sure no water is leaking in the system.