Jason B.

Jason B. Job Checkin

I came out to remove old equipment and do a full install. I installed a Five Star 13 SEER, 3 Ton Air Conditioner and a Five Star 96% 60k BTU Up-Flow Gas Furnace

I came out to remove old equipment and do a full install. I installed a Five Star 13 SEER, 3 Ton Air Conditioner and a Five Star 96% 60k BTU Up-Flow Gas Furnace

Randal S.

Randal S. Job Checkin

Upon arrival I completed diagnostics and found the system out of charge spoke with service manager about call please see notes. No charge for call.


Jesse S.

Jesse S. Job Checkin

I completed a Scheduled Maintenance Agreement Tune-Up and Safety Check. Visually inspected unit and found no issues at this time.


Jesse S.

Jesse S. Job Checkin

I completed the scheduled maintenance agreement fall tune up on a 2021 gas furnace. i visually inspected the unit. Checked voltages, amps and pressures. Completed combustion analysis. Cycled and monitored system. Operating normally at the time of departure.


Josh A.

Josh A. Job Checkin

Called to see why furnace not properly functioning. Found code for high pressure switch code, while checking drain noticed green vac tube not connected. Reconnected and system properly functioning upon departure.

Called to see why furnace not properly functioning. Found code for high pressure switch code, while checking drain noticed green vac tube not connected. Reconnected and system properly functioning upon departure.

Lucas M.

Lucas M. Job Checkin

Upon arrival I completed a Full Install of a Five Star Multi-Speed Electric Furnace FSGRUF/FSGSPT (Up to 3 ton) Honeywell T10 Programmable Thermostat Five Star 14 SEER Heat Pump FSGSZ14 (Up to 3 ton). The system is operational upon departure.

Upon arrival I completed a Full Install of a Five Star Multi-Speed Electric Furnace FSGRUF/FSGSPT (Up to 3 ton) Honeywell T10 Programmable Thermostat Five Star 14 SEER Heat Pump FSGSZ14 (Up to 3 ton). The system is operational upon departure.

Shane C.

Shane C. Job Checkin

Upon arrival I completed a Full Install of a FEATURED DEAL Five Star Multi-Speed Electric Furnace FSGRUF/FSGSPT (Up to 3 ton) Honeywell T10 Programmable Thermostat Five Star 14 SEER Heat Pump FSGSZ14 (Up to 3 ton). The system is operational upon departure.

Upon arrival I completed a Full Install of a FEATURED DEAL
Five Star Multi-Speed Electric Furnace FSGRUF/FSGSPT (Up to 3 ton)
Honeywell T10 Programmable Thermostat Five Star 14 SEER Heat Pump FSGSZ14 (Up to 3 ton). The system is operational upon departure.

Randal S.

Randal S. Job Checkin

I completed a callback service. I Found drain line leaking, sloped and cut out bad joints, found gas pressures at 1.4 and 5.4 set pressures for 5.0 and 9.5 couldn’t go higher than 9.5 regulator needs turned up, system operating as intended upon departure.


Aaron B.

Aaron B. Job Checkin

I performed a tune up and safety check on a Carrier 96% Two-Stage 80,000 BTU Gas Furnace. I pulled and cleaned the flame sensor and found no issues. The furnace was operational and heating when I left.

I performed a tune up and safety check on a Carrier 96% Two-Stage 80,000 BTU Gas Furnace.  I pulled and cleaned the flame sensor and found no issues.  The furnace was operational and heating when I left.

Adam N.

Adam N. Job Checkin

I completed a heating tune up on a Trane electric furnace. I visually inspected the unit. Checked voltages, amps and pressures. Completed combustion analysis. Cycled and monitored system. Operating normally at this time.

I completed a heating tune up on a Trane electric furnace.  I visually inspected the unit.  Checked voltages, amps and pressures.  Completed combustion analysis.  Cycled and monitored system.  Operating normally at this time.

Jacob M.

Jacob M. Job Checkin

I completed a heating tune up on a Trane electric furnace. I visually inspected the unit. Checked voltages, amps and pressures. Completed combustion analysis. Cycled and monitored system. Operating normally at this time.

I completed a heating tune up on a Trane electric furnace. I visually inspected the unit. Checked voltages, amps and pressures. Completed combustion analysis. Cycled and monitored system. Operating normally at this time.