Noah B.

Noah B.


Job Checkin

Found furnace locked out, flashing alternating slow, pressure switch trip. Upon departure I found the condensate trap clogged. I blew it out, cycled the power and the system is now heating, Propane furnace 18 years old, recommend regular maintenance and replacement is in its future. Lennox

Found furnace locked out, flashing alternating slow, pressure switch trip.

Upon departure I found the condensate trap clogged. I blew it out, cycled the power and the system is now heating, Propane furnace 18 years old, recommend regular maintenance and replacement is in its future. Lennox