Haidar H.

Haidar H. Job Checkin

Inspection of a 3 Ton Trane cooling system confirmed the furnace has a faulty circuit board. The board is not calling for the blower to come on for heating or cooling.

Inspection of a 3 Ton Trane cooling system confirmed the furnace has a faulty circuit board. The board is not calling for the blower to come on for heating or cooling.

Haidar H.

Haidar H. Job Checkin

Free second diagnostic opinion given for a 2002 Carrier cooling system. Confirmed major leak in system and unit has zero refrigerant. Estimate given to replace with a Carrier 13 SEER 3 Ton Air Conditioner.

Free second diagnostic opinion given for a 2002 Carrier cooling system. Confirmed major leak in system and unit has zero refrigerant. Estimate given to replace with a Carrier 13 SEER 3 Ton Air Conditioner.

Haidar H.

Haidar H. Job Checkin

Outdoor unit had a blown capacitor. Replaced capacitor, system working within specs.

	
Outdoor unit had a blown capacitor.

Replaced capacitor,  system working within specs.

Haidar H.

Haidar H. Job Checkin

Found a blown capacitor, replaced capacitor system cooling within specs


Haidar H.

Haidar H. Job Checkin

Replacement of a Dual Capacitor and Fuse 25-50 amp Bar completed on a Goodman Air Conditioner.

Replacement of a Dual Capacitor and Fuse 25-50 amp Bar completed on a Goodman Air Conditioner.

Haidar H.

Haidar H. Job Checkin

Diagnostic performed over a Trane cooling system and found the outdoor fan motor comes on but the compressor does not. After ohming the compressor I found a bad compressor. Recommended to either replace the compressor or cooling system. Estimates provided to replace with a 5 Ton Carrier AC.

Diagnostic performed over a Trane cooling system and found the outdoor fan motor comes on but the compressor does not. After ohming the compressor I found a bad compressor. Recommended to either replace the compressor or cooling system. Estimates provided to replace with a 5 Ton Carrier AC.

Haidar H.

Haidar H. Job Checkin

Error code 79 keeps coming on Carrier "Infinity Series" 19 SEER Variable-Speed 2 Ton Air Conditioner, wiring to unit had been chewed up, tech replaced wiring and unit is running within manufactures specs

Error code 79 keeps coming on Carrier "Infinity Series" 19 SEER Variable-Speed 2 Ton Air Conditioner, wiring to unit had been chewed up, tech replaced wiring and unit is running within manufactures specs