Have any feedback for us? We'd love to hear it! Call us at (864) 310-7704 and let us know how we are doing.
Performed annual maintenance on A.O. Smith 40-gal gas water heater. Flushed tank to remove sediment buildup (substantial amount). Inspected heating element, anode rod (needs replacement within 6 months), and pressure relief valve. Adjusted temperature to 120°F for safety and efficiency. Checked gas connections with leak detector—all secure. Water heater is 8 years old but should provide several more years of service with regular maintenance. Will schedule follow-up for anode replacement.
Performed routine AC maintenance. Unit is a Trane XR14, approximately 5 years old. Inspected and cleaned condenser coils, which showed minimal debris accumulation. Changed air filter (customer enrolled in our filter program). Checked refrigerant pressures - within manufacturer specifications. Inspected ductwork connections near unit - all secure. Thermostat calibration verified. System operating at expected efficiency. Recommend scheduling fall furnace check before heating season begins.
Performing repairs to a carrier split air conditioning system with a natural gas furnace unit low on Freon add sealer and replace cap capacitor
Repairs and maintenance to Lennox equipment and Simpsonville, South Carolina