Changed 5a fuse on board from low voltage short and got ac cooling back properly


carsonb@callproservices.com

carsonb@callproservices.com Job Checkin

Estimate to install 50 gallon electric water heater in basement. The water heater is busted on the bottom and is leaking out into the crawlspace. The water heater needs to be replaced. Also found that the water pressure on the house is 125 psi. The PRV will need to be changed out as well to get the water pressure back to where it needs to be. I will also add an expansion tank to the water heater to get it up to code. There is already a disconnect that is going to the water heater so we do not need a electrician to come out to install a disconnect. I will also install a water heater pan to go under the water heater so that way it’s not sitting directly on wood or the floor. Install new 50 gallon electric water heater. I had an expansion tank and a three-quarter PRV. Put water heater in pan as well.


carsonb@callproservices.com

carsonb@callproservices.com Job Checkin

Sold 50 gallon electric water heater for Friday morning. Will need to install a PRV expansion tank and a pan for the water heater.


brodyb@callproservices.com

brodyb@callproservices.com Job Checkin

Arrived today for repair on 2017 2.5 ton Rheem heat pump system. Cleaned system changed filter 20x25x1 customer supplied. Replaced defrost control board capacitor and contactor. Checked refrigerant level amps on motors and safety controls. Everything is working properly at this time.


brodyb@callproservices.com

brodyb@callproservices.com Job Checkin

Arrived today for no cooling on 2017 2.5 ton Rheem heat pump system. Found defrost control board on outdoor unit needs replaced and system needs serviced and cleaned. Gave customer options. Membership. Scheduled with office to go back Friday for repair and clean system.


trentm@callproservices.com

trentm@callproservices.com Job Checkin

Replace single handle delta shower cartridge


brodyb@callproservices.com

brodyb@callproservices.com Job Checkin

Pumped 750 gallon septic tank


brodyb@callproservices.com

brodyb@callproservices.com Job Checkin

Gave estimate to install sink


trentm@callproservices.com

trentm@callproservices.com Job Checkin

Pull toilet Repair water leak Reset toilet Leak check 30 day warranty


trentm@callproservices.com

trentm@callproservices.com Job Checkin

Replace thermostat


brodyb@callproservices.com

brodyb@callproservices.com Job Checkin

gave options and also gave financing options


pedrop@callproservices.com

pedrop@callproservices.com Job Checkin

New upgrade service includes New 200 amps meter combo New 2” mask with eyebolt and weather head 4/o wire 200 amps 3/o 4/4 wire for sub panel. Inside New sub panel 100 amps New ground system panels, water lines and gas lines Full home suger protector Water heater disconnect New breakers on every panel 2 year warranty parts and labor Everything by code The Works Membership Priority Scheduling No service fee during normal business hours 10% discount 2 times a year hvac service up to 2 systems plumbing inspection and water heater flush Electrical inspection


brodyb@callproservices.com

brodyb@callproservices.com Job Checkin

jetted Two floor drains plus main clean out for drains to oil separator pit


carsonb@callproservices.com

carsonb@callproservices.com Job Checkin

Estimate to do a Gas pressure test on the house Installed new vent pipe in Addis now there are no rust spots on the vent pipe. Also repaired gas line where it was leaking into the crawlspace. Everything is good to go in. The gas line is holding pressure.


pedrop@callproservices.com

pedrop@callproservices.com Job Checkin

This is a house making up arc spark on gas line, because doesn’t have any ground system protecting or recommendation is House needs an upgrade service I talked with Miss Suzy , and she’s going to talk with her boss about it. I’ll send multiple options on how to fix the problem on this house, she’s gonna call us back with a decision